A coarse‐to‐fine framework combining deep learning and Monte Carlo for BNCT patient position optimization toward inverse planning

Yoonho Na, Chang-Min Lee, Kyuri Kim, Hyungjoo Cho, Jimin Lee, Sung-Joon Ye

Medical Physics · 2026

DOI: 10.1002/mp.70642 ↗

At a glance

Journal article in Medical Physics, 2026. Written by Yoonho Na and 5 co-authors. Institution: Department of Applied Bioengineering, Seoul National University, Seoul, Republic of Korea. Major MEDLINE topics: Monte Carlo Method, Boron Neutron Capture Therapy, Radiotherapy Planning, Computer-Assisted, Deep Learning. 37 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Research Foundation of Korea, Korea government (MSIT), Ministry of Education.

SamenvattingSubjectsBibliografische gegevensCiteRelated studies

Abstract (original language)

Background

Boron Neutron Capture Therapy (BNCT) utilizes high linear energy transfer (LET) charged particles from the 10 B(n,α) 7 Li reaction to selectively destroy tumor cells. Unlike conventional radiation therapy, BNCT facilities rely on fixed beam ports, making patient positioning critical in treatment planning. Current treatment planning, however, depends on manual forward planning using computationally intensive Monte Carlo (MC) simulations.

Purpose

We propose an automated patient position optimization framework for BNCT to address these limitations. This method overcomes the computational bottleneck of MC simulations by integrating a rapid deep learning (DL) dose prediction model with a high‐fidelity GPU‐accelerated MC engine, enabling efficient inverse planning.

Methods

We developed a hybrid coarse‐to‐fine optimization workflow driven by the Trust Region Bayesian Optimization (TuRBO) algorithm. In the coarse stage, a 3D U‐Net architecture rapidly identifies promising patient positions. In the fine stage, the solution is refined within a restricted parameter bound using the GPU‐accelerated MC engine. We evaluated the framework on the GLIS‐RT open dataset (229 glioblastoma patients, split into train, validation, and test sets at a 70:20:10 ratio).

Results

Optimizing the patient position with TuRBO improved target dose and homogeneity over a non‐optimized baseline, reaching equivalent plan quality about 5.65× faster than an exhaustive grid search. In the coarse stage, the DL dose predictor ran about 37× faster than the high‐fidelity MC. The coarse‐to‐fine workflow then matched high‐fidelity MC plan quality while cutting optimization time by a factor of 2.7, outperforming optimization driven by the DL predictor alone. Two‐port plans required no change to the method, where the added geometric freedom raised the mean target dose from 59.96% to 74.91% and lowered the homogeneity index (HI) from 1.226 to 0.647.

Conclusions

We successfully developed a Bayesian optimization (BO) framework for BNCT patient positioning. The proposed coarse‐to‐fine approach effectively balances computational speed with accuracy, offering a practical way toward automated inverse planning in BNCT.

Subjects

MeSH terms (MEDLINE)

Monte Carlo MethodBoron Neutron Capture TherapyRadiotherapy Planning, Computer-AssistedDeep LearningPatient PositioningHumansRadiotherapy DosageBayes Theorem

Author keywords

BNCTBayesian optimizationMonte Carlodeep learninginverse planningpatient positioning

Authors and institutions

  • Department of Applied Bioengineering, Seoul National University, Seoul, Republic of Korea.
  • T-ROH Inc., Seoul, Republic of Korea.
  • Atherosoft Inc., Seoul, Republic of Korea.
  • Department of Nuclear Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea.
  • Research Institute for Convergence Science, Seoul National University, Seoul, Republic of Korea.
  • Advanced Institute of Convergence Technology, Seoul National University, Suwon, Republic of Korea.

Funding

  • National Research Foundation of Korea
  • Korea government (MSIT)
  • Ministry of Education
  • Kementerian Pendidikan

Cite

APA

Na, Y., Lee, C. M., Kim, K., Cho, H., Lee, J., & Ye, S. J. (2026). A coarse‐to‐fine framework combining deep learning and Monte Carlo for BNCT patient position optimization toward inverse planning. Medical Physics. https://doi.org/10.1002/mp.70642

Vancouver

Na Y, Lee CM, Kim K, Cho H, Lee J, Ye SJ. A coarse‐to‐fine framework combining deep learning and Monte Carlo for BNCT patient position optimization toward inverse planning. Medical Physics. 2026. doi:10.1002/mp.70642

BibTeX
@article{Na2026,
  author = {Na, Yoonho and Lee, Chang-Min and Kim, Kyuri and Cho, Hyungjoo and Lee, Jimin and Ye, Sung-Joon},
  title = {A coarse‐to‐fine framework combining deep learning and Monte Carlo for BNCT patient position optimization toward inverse planning},
  journal = {Medical Physics},
  year = {2026},
  doi = {10.1002/mp.70642}
}
Start for free →