Physics‐informed patient‐specific calibration for monocular visual‐based dose reconstruction in breast cancer radiotherapy

Yongjin Deng, Xuecen Wang, Ruiwan Chen

Medical Physics · 2026-07 · 53 (7)

DOI: 10.1002/mp.70533 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 25.06.2026. Verfasst von Yongjin Deng und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Radiation Dosage, Radiotherapy, Image-Guided, Image Processing, Computer-Assisted. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Interfractional anatomical variations during breast cancer radiotherapy can significantly deviate the delivered dose from the treatment plan. Standard image guidance via Cone‐Beam CT (CBCT) is typically sparse due to radiation and workflow constraints, leaving daily geometric changes unmonitored.

Purpose

To bridge this gap, we propose a physics‐informed framework that utilizes monocular surface vision for continuous, non‐ionizing 3D dose reconstruction.

Methods

The system utilizes the weekly CBCT scans from the first 2 weeks of treatment (Week 1 and Week 2) for patient‐specific calibration. Surface features are extracted via a hybrid HOG‐CNN descriptor, while 3D deformation vector fields (DVFs) are compressed into a low‐dimensional latent space via Principal Component Analysis (PCA). A linear mapping from surface topography to PCA coefficients is optimized using physics‐informed Tikhonov regularization, incorporating an eigenvalue‐based penalty matrix to suppress high‐order non‐physical modes. Post‐calibration, the model reconstructs 3D dose distributions for subsequent fractions in real time using only monocular input.

Results

Validated on 29 patients (87 fractions), the framework achieved a deformation coefficient correlation of R = 0.796. Reconstructed doses yielded a mean Gamma passing rate (3%/3 mm) of 93.8% ± 3.1% and a dose correlation of 0.940 ± 0.037. Ablation studies demonstrated that removing physics constraints or PCA reduction significantly degraded performance (ΔGPR = −8.5% and −22.1%, respectively; p < 0.001). End‐to‐end latency was 42 ± 5 ms per fraction, representing a ∼124‐fold acceleration over commercial deformable registration solutions.

Conclusions

This framework transforms routine weekly CBCTs into robust “calibration anchors” for continuous visual dose monitoring. It provides clinical‐grade accuracy with negligible computational overhead and no additional ionizing dose, offering a practical solution for real‐time adaptive radiotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsRadiation DosageRadiotherapy, Image-GuidedImage Processing, Computer-AssistedRadiotherapy Planning, Computer-AssistedHumansCalibrationRadiotherapy DosageCone-Beam Computed TomographyFemalePhysics

Stichwörter der Autor:innen

breast cancer radiotherapydose reconstructionmonocular visionpatient‐specific calibrationphysics‐informed learning

Autor:innen und Institutionen

  • Department of Radiation Oncology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.

Zitieren

APA

Deng, Y., Wang, X., & Chen, R. (2026). Physics‐informed patient‐specific calibration for monocular visual‐based dose reconstruction in breast cancer radiotherapy. Medical Physics, 53(7). https://doi.org/10.1002/mp.70533

Vancouver

Deng Y, Wang X, Chen R. Physics‐informed patient‐specific calibration for monocular visual‐based dose reconstruction in breast cancer radiotherapy. Medical Physics. 2026;53(7). doi:10.1002/mp.70533

BibTeX
@article{Deng2026,
  author = {Deng, Yongjin and Wang, Xuecen and Chen, Ruiwan},
  title = {Physics‐informed patient‐specific calibration for monocular visual‐based dose reconstruction in breast cancer radiotherapy},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {7},
  doi = {10.1002/mp.70533}
}
Kostenlos starten →