Deep learning based super‐resolution for CBCT dose reduction in radiotherapy
Medical Physics · 2025-03 · 52 (3) · 1629-1642
DOI: 10.1002/mp.17557 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 03.12.2024. Verfasst von Adrian Thummerer und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany. Hauptthemen laut MEDLINE: Deep Learning, Cone-Beam Computed Tomography, Radiation Dosage, Radiotherapy, Image-Guided. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Deutsche Krebshilfe.
Abstract (Originalsprache)
Background
Cone‐beam computed tomography (CBCT) is a crucial daily imaging modality in image‐guided and adaptive radiotherapy. However, the use of ionizing radiation in CBCT imaging increases the risk of secondary cancers, which is particularly concerning for pediatric patients. Deep learning super‐resolution has shown promising results in enhancing the resolution of photographic and medical images but has not yet been explored in the context of CBCT dose reduction.
Purpose
To facilitate CBCT imaging dose reduction, we propose using an enhanced super‐resolution generative adversarial network (ESRGAN) in both the projection and image domains to restore the image quality of low‐dose CBCT.
Methods
An extensive projection database, containing 2997 CBCT scans from head and neck cancer patients, was used to train two different ESRGAN models to generate super‐resolution CBCTs. One model operated in the projection domain, using pairs of simulated low‐resolution (low‐dose) and original high‐resolution (high‐dose) projections and yielded CBCT SRpro . The other model operated in the image domain, using pairs of axial slices from reconstructed low‐resolution and high‐resolution CBCTs (CBCT LR and CBCT HR ) and resulted in CBCT SRimg . Super‐resolution CBCTs were evaluated in terms of image similarity (MAE, ME, PSNR, and SSIM), noise characteristics, spatial resolution, and registration accuracy, using the original CBCT as a reference. To test the perceptual difference between the original and super‐resolution CBCT, we performed a visual Turing test.
Results
Visually, both super‐resolution approaches in the projection and image domains improved the image quality of low‐dose CBCTs. This was confirmed by the visual Turing test, that showed low accuracy, sensitivity, and specificity, indicating almost no perceptual difference between CBCT HR and the super‐resolution CBCTs. CBCT SRimg (accuracy: 0.55, sensitivity: 0.59, specificity: 0.50) performed slightly better than CBCT SRpro (accuracy: 0.59, sensitivity: 0.61, specificity: 0.57). Image similarity metrics were affected by varying noise levels and did not reflect the visual improvements, with MAE/ME/PSNR/SSIM values of 110.4 HU/2.9 HU/40.4 dB/0.82 for CBCT LR , 136.6 HU/−0.4 HU/38.6 dB/0.77 for CBCT SRpro , and 128.2 HU/1.9 HU/39.0 dB/0.80 for CBCT SRimg . In terms of spatial resolution, quantified by calculating 10% levels of the task transfer function, both CBCT SRpro and CBCT SRimg outperformed CBCT LR and nearly matched the reference CBCT HR (CBCT LR : 0.66 lp/mm, CBCT SRpro : 0.88 lp/mm, CBCT SRimg : 0.95 lp/mm, CBCT HR : 1.01 lp/mm). Noise characteristics of CBCT SRimg and CBCT SRpro were comparable to the reference CBCT HR . Registration parameters showed negligible differences for all CBCTs (CBCT LR , CBCT SRpro , CBCT SRimg ), with average absolute differences in registration parameters being below 0.4° for rotations and below 0.06 mm for translations (CBCT HR as reference).
Conclusions
This study demonstrates that deep learning can be a valuable tool for CBCT dose reduction in CBCT‐guided radiotherapy by acquiring low‐dose CBCTs and restoring the image quality using deep learning super‐resolution. The results suggest that higher quality images can be generated when super‐resolution is performed in the image domain compared to the projection domain.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany.
- German Cancer Consortium (DKTK), Partner Site Munich, A Partnership Between DKFZ and LMU University Hospital Munich Germany, Munich, Germany.
- Bavarian Cancer Research Center (BZKF), Munich, Germany.
Förderung
- Deutsche Krebshilfe
Zitieren
APA
Thummerer, A., Schmidt, L., Hofmaier, J., Corradini, S., Belka, C., Landry, G., & Kurz, C. (2025). Deep learning based super‐resolution for CBCT dose reduction in radiotherapy. Medical Physics, 52(3), 1629-1642. https://doi.org/10.1002/mp.17557
Vancouver
Thummerer A, Schmidt L, Hofmaier J, Corradini S, Belka C, Landry G, et al. Deep learning based super‐resolution for CBCT dose reduction in radiotherapy. Medical Physics. 2025;52(3):1629-1642. doi:10.1002/mp.17557
BibTeX
@article{Thummerer2025,
author = {Thummerer, Adrian and Schmidt, Lukas and Hofmaier, Jan and Corradini, Stefanie and Belka, Claus and Landry, Guillaume and Kurz, Christopher},
title = {Deep learning based super‐resolution for CBCT dose reduction in radiotherapy},
journal = {Medical Physics},
year = {2025},
volume = {52},
number = {3},
pages = {1629--1642},
doi = {10.1002/mp.17557}
}
EUVIMED