First implementation of an innovative infra‐red camera system integrated into a mobile CBCT scanner for applicator tracking in brachytherapy—Initial performance characterization

Andre Karius iD, Lisa Marie Leifeld, Vratislav Strnad, Rainer Fietkau, Christoph Bert

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14364 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Andre Karius und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Brachytherapy, Phantoms, Imaging, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To enable a real‐time applicator guidance for brachytherapy, we used for the first time infra‐red tracking cameras (OptiTrack, USA) integrated into a mobile cone‐beam computed tomography (CBCT) scanner (medPhoton, Austria). We provide the first description of this prototype and its performance evaluation.

Methods

We performed assessments of camera calibration and camera‐CBCT registration using a geometric calibration phantom. For this purpose, we first evaluated the effects of intrinsic parameters such as camera temperature or gantry rotations on the tracked marker positions. Afterward, calibrations with various settings (sample number, field of view coverage, calibration directions, calibration distances, and lighting conditions) were performed to identify the requirements for achieving maximum tracking accuracy based on an in‐house phantom. The corresponding effects on camera‐CBCT registration were determined as well by comparing tracked marker positions to the positions determined via CBCT. Long‐term stability was assessed by comparing tracking and a ground‐truth on a weekly basis for 6 weeks.

Results

Robust tracking with positional drifts of 0.02 ± 0.01 mm was feasible using the system after a warm‐up period of 90 min. However, gantry rotations affected the tracking and led to inaccuracies of up to 0.70 mm. We identified that 4000 samples and full coverage were required to ensure a robust determination of marker positions and camera‐CBCT registration with geometric deviations of 0.18 ± 0.03 mm and 0.42 ± 0.07 mm, respectively. Long‐term stability showed deviations of more than two standard deviations from the initial calibration after 3 weeks.

Conclusion

We implemented for the first time a standalone combined camera‐CBCT system for tracking in brachytherapy. The system showed high potential for establishing corresponding workflows.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyBrachytherapyPhantoms, ImagingRadiotherapy Planning, Computer-AssistedRadiotherapy, Image-GuidedRadiotherapy DosageHumansCalibrationImage Processing, Computer-AssistedRadiotherapy, Intensity-ModulatedNeoplasms

Stichwörter der Autor:innen

brachytherapycombined camera‐CT systeminfra‐red applicator trackingsystem characterization

Autor:innen und Institutionen

  • Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany.

ORCID-Profile: Andre Karius

Zitieren

APA

Karius, A., Leifeld, L. M., Strnad, V., Fietkau, R., & Bert, C. (2024). First implementation of an innovative infra‐red camera system integrated into a mobile CBCT scanner for applicator tracking in brachytherapy—Initial performance characterization. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14364

Vancouver

Karius A, Leifeld LM, Strnad V, Fietkau R, Bert C. First implementation of an innovative infra‐red camera system integrated into a mobile CBCT scanner for applicator tracking in brachytherapy—Initial performance characterization. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14364

BibTeX
@article{Karius2024,
  author = {Karius, Andre and Leifeld, Lisa Marie and Strnad, Vratislav and Fietkau, Rainer and Bert, Christoph},
  title = {First implementation of an innovative infra‐red camera system integrated into a mobile CBCT scanner for applicator tracking in brachytherapy—Initial performance characterization},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14364}
}
Kostenlos starten →