EUVIMEDOdkrijte EUVIMED
VergleichsstudieOpen access · CC BY-NC-ND 4.0

A Monte Carlo study of proton LET calculations: Comparison between the codes PENHAN, FLUKA, and TOPAS

D Puerta, M Anguiano, W González

Medical Physics · 2026-03 · 53 (3)

DOI: 10.1002/mp.70378 ↗

At a glance

Vergleichsstudie in Medical Physics, published online on 2026-03-08. Written by D Puerta and 2 co-authors. Institution: Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, Granada, Spain. Major MEDLINE topics: Monte Carlo Method, Linear Energy Transfer, Protons. Cited 1 times so far (Crossref); 51 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Consejería de Universidad, Investigación e Innovación. Junta de Andalucía, Ministerio de Ciencia, Innovación y Universidades. Agencia Estatal de Investigación, Universidad de Granada / CBUA: funding for open access charge.

PovzetekSubjectsBibliografski podatkiCiteRelated studies

Abstract (original language)

Background

Linear energy transfer (LET) is frequently used to characterize radiation quality in proton therapy and is an important quantity for radiobiological modeling. However, LET calculations can, in principle, vary between Monte Carlo (MC) codes, affecting consistency in treatment planning and relative biological effectiveness (RBE) estimation.

Purpose

This study aims to investigate the variability of LET results when using different MC codes.

Methods

An intercomparison of LET results was performed using penhan , topas MC, and CERN fluka , together with recently published experimental data. Track‐averaged () and dose‐averaged () LET were evaluated under different irradiation configurations, including pencil and broad beams, with and without nuclear reactions.

Results

The results obtained indicate that discrepancies in LET calculations are primarily linked to the choice of stopping powers and the handling of nuclear interactions. Calculations considering only primary protons exhibited great agreement with recent experimental LET measurements, validating our simulations. Conclusions showed higher robustness and consistency across codes, suggesting it as potentially a more reliable metric for LET‐based treatment planning and RBE modeling. Our findings emphasize the importance of consistent LET calculations, result reporting, and code benchmarking in proton therapy calculations.

Subjects

MeSH terms (MEDLINE)

Monte Carlo MethodLinear Energy TransferProtonsProton TherapyRelative Biological EffectivenessRadiotherapy Planning, Computer-Assisted

Author keywords

LETMonte Carlo simulationproton therapy

Substances

Protons

Authors and institutions

  • Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, Granada, Spain.
  • Instituto de Investigación Biosanitaria, Granada, Spain.
  • Departamento de Física Aplicada I, Universidad de Málaga, Málaga, Spain.

Funding

  • Consejería de Universidad, Investigación e Innovación. Junta de Andalucía
  • Ministerio de Ciencia, Innovación y Universidades. Agencia Estatal de Investigación
  • Universidad de Granada / CBUA: funding for open access charge

Cite

APA

Puerta, D., Anguiano, M., & González, W. (2026). A Monte Carlo study of proton LET calculations: Comparison between the codes PENHAN, FLUKA, and TOPAS. Medical Physics, 53(3). https://doi.org/10.1002/mp.70378

Vancouver

Puerta D, Anguiano M, González W. A Monte Carlo study of proton LET calculations: Comparison between the codes PENHAN, FLUKA, and TOPAS. Medical Physics. 2026;53(3). doi:10.1002/mp.70378

BibTeX
@article{Puerta2026,
  author = {Puerta, D and Anguiano, M and González, W},
  title = {A Monte Carlo study of proton LET calculations: Comparison between the codes PENHAN, FLUKA, and TOPAS},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {3},
  doi = {10.1002/mp.70378}
}
Start for free →