Beyond a constant proton relative biological effectiveness: A survey of clinical and research perspectives among proton institutions in Europe and the United States
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.14535 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Jakob Ödén und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Research, RaySearch Laboratories AB, Stockholm, Sweden. Hauptthemen laut MEDLINE: Relative Biological Effectiveness, Proton Therapy, Protons, Linear Energy Transfer. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Although proton relative biological effectiveness (RBE) depends on factors like linear energy transfer (LET), tissue properties, dose, and biological endpoint, a constant RBE of 1.1 is recommended in clinical practice. This study surveys proton institutions to explore activities using functionalities beyond a constant proton RBE.
Methods
Research versions of RayStation integrate functionalities considering variable proton RBE, LET, proton track‐ends, and dirty dose. A survey of 19 institutions in Europe and the United States, with these functionalities available, investigated clinical adoption and research prospects using a 25‐question online questionnaire.
Results
Of the 16 institutions that responded (84% response rate), 13 were clinically active. These clinical institutions prescribe RBE = 1.1 but also employ planning strategies centered around special beam arrangements to address potentially enhanced RBE effects in serially structured organs at risk (OARs). Clinical plan evaluation encompassed beam angles/spot position (69%), dose‐averaged LET (LET d ) (46%), and variable RBE distributions (38%). High ratings (discrete scale: 1–5) were reported for the research functionalities using linear LET d ‐RBE models, LET d , track‐end frequency and dirty dose (averages: 4.0–4.8), while LQ‐based phenomenological RBE models dependent on LET d scored lower for optimization (average: 2.2) but congruent for evaluation (average: 4.1). The institutions preferred LET reported as LET d (94%), computed in unit‐density water (56%), for all protons (63%), and lean toward LET d ‐based phenomenological RBE models for clinical use (> 50%).
Conclusions
Proton institutions recognize RBE variability but adhere to a constant RBE while actively mitigating potential enhancements, particularly in serially structured OARs. Research efforts focus on planning techniques that utilize functionalities beyond a constant RBE, emphasizing standardized LET and RBE calculations to facilitate their adoption in clinical practice and improve clinical data collection. LET d calculated in unit‐density water for all protons as input to adaptable phenomenological RBE models was the most suggested approach, aligning with predominant clinical LET and variable RBE reporting.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Research, RaySearch Laboratories AB, Stockholm, Sweden.
ORCID-Profile: Jakob Ödén, Suryakant Kaushik
Zitieren
APA
Ödén, J., Eriksson, K., Kaushik, S., & Traneus, E. (2025). Beyond a constant proton relative biological effectiveness: A survey of clinical and research perspectives among proton institutions in Europe and the United States. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14535
Vancouver
Ödén J, Eriksson K, Kaushik S, Traneus E. Beyond a constant proton relative biological effectiveness: A survey of clinical and research perspectives among proton institutions in Europe and the United States. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.14535
BibTeX
@article{dn2025,
author = {Ödén, Jakob and Eriksson, Kjell and Kaushik, Suryakant and Traneus, Erik},
title = {Beyond a constant proton relative biological effectiveness: A survey of clinical and research perspectives among proton institutions in Europe and the United States},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.14535}
}
EUVIMED