EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Linear Energy Transfer Measurements and Estimation of Relative Biological Effectiveness in Proton and Helium Ion Beams Using Fluorescent Nuclear Track Detectors

Iván D Muñoz, Daniel García-Calderón, Renato Felix-Bautista, Lucas N Burigo, Jeppe Brage Christensen, Stephan Brons, Armin Runz, Peter Häring, Steffen Greilich, Joao Seco, Oliver Jäkel

International Journal of Radiation Oncology*Biology*Physics · 2024

DOI: 10.1016/j.ijrobp.2024.02.047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Radiation Oncology*Biology*Physics, 2024. Verfasst von Iván D Muñoz und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany; Division of Medical Physics in Radiation Oncology, German Cancer …. Hauptthemen laut MEDLINE: Linear Energy Transfer, Relative Biological Effectiveness, Helium, Monte Carlo Method. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: German Academic Exchange Service.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Our objective was to develop a methodology for assessing the linear energy transfer (LET) and relative biological effectiveness (RBE) in clinical proton and helium ion beams using fluorescent nuclear track detectors (FNTDs). METHODS AND MATERIALS: FNTDs were exposed behind solid water to proton and helium (4He) ion spread-out Bragg peaks. Detectors were imaged with a confocal microscope, and the LET spectra were derived from the fluorescence intensity. The track- and dose-averaged LET (LETF and LETD, respectively) were calculated from the LET spectra. LET measurements were used as input on RBE models to estimate the RBE. Human alveolar adenocarcinoma cells (A549) were exposed at the same positions as the FNTDs. The RBE was calculated from the resulting survival curves. All measurements were compared with Monte Carlo simulations. RESULTS: For protons, average relative differences between measurements and simulations were 6% and 19% for LETF and LETD, respectively. For helium ions, the same differences were 11% for both quantities. The position of the experimental LET spectra primary peaks agreed with the simulations within 9% and 14% for protons and helium ions, respectively. For the RBE models using LETD as input, FNTD-based RBE values ranged from 1.02 ± 0.01 to 1.25 ± 0.04 and from 1.08 ± 0.09 to 2.68 ± 1.26 for protons and helium ions, respectively. The average relative differences between these values and simulations were 2% and 4%. For A549 cells, the RBE ranged from 1.05 ± 0.07 to 1.47 ± 0.09 and from 0.89 ± 0.06 to 3.28 ± 0.20 for protons and helium ions, respectively. Regarding the RBE-weighted dose (2.0 Gy at the spread-out Bragg peak), the differences between simulations and measurements were below 0.10 Gy. CONCLUSIONS: This study demonstrates for the first time that FNTDs can be used to perform direct LET measurements and to estimate the RBE in clinical proton and helium ion beams.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Linear Energy TransferRelative Biological EffectivenessHeliumMonte Carlo MethodHumansProton TherapyA549 CellsProtonsMicroscopy, Confocal

Substanzen

HeliumProtons

Autor:innen und Institutionen

  • Department of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany; Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Heidelberg Institute for…
  • Department of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany; Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany; Div…
  • Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO)…
  • Department of Radiation Safety and Security, Paul Scherrer Institute (PSI), Villigen, Switzerland.
  • Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany; Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg…
  • Berthold Technologies GmbH & Co KG, Units of Radiation Protection and Bioanalytics, Bad Wildbad, Germany.

Förderung

  • German Academic Exchange Service

Zitieren

APA

Muñoz, I. D., García-Calderón, D., Felix-Bautista, R., Burigo, L. N., Christensen, J. B., Brons, S., Runz, A., Häring, P., Greilich, S., Seco, J., & Jäkel, O. (2024). Linear Energy Transfer Measurements and Estimation of Relative Biological Effectiveness in Proton and Helium Ion Beams Using Fluorescent Nuclear Track Detectors. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/j.ijrobp.2024.02.047

Vancouver

Muñoz ID, García-Calderón D, Felix-Bautista R, Burigo LN, Christensen JB, Brons S, et al. Linear Energy Transfer Measurements and Estimation of Relative Biological Effectiveness in Proton and Helium Ion Beams Using Fluorescent Nuclear Track Detectors. International Journal of Radiation Oncology*Biology*Physics. 2024. doi:10.1016/j.ijrobp.2024.02.047

BibTeX
@article{Muoz2024,
  author = {Muñoz, Iván D and García-Calderón, Daniel and Felix-Bautista, Renato and Burigo, Lucas N and Christensen, Jeppe Brage and Brons, Stephan and Runz, Armin and Häring, Peter and Greilich, Steffen and Seco, Joao and Jäkel, Oliver},
  title = {Linear Energy Transfer Measurements and Estimation of Relative Biological Effectiveness in Proton and Helium Ion Beams Using Fluorescent Nuclear Track Detectors},
  journal = {International Journal of Radiation Oncology*Biology*Physics},
  year = {2024},
  doi = {10.1016/j.ijrobp.2024.02.047}
}
Kostenlos starten →