EUVIMEDEUVIMED entdecken
Crossref

A regularized‐multi‐field optimization algorithm for robust IMPT

Ying Luo, Chao Wang, Ya-Nan Zhu, Wangyao Li, Daniel Johnson, Yuting Lin, David Akhavan, Krishna Reddy, Carolyn Savioz, Qiang Li, Hao Gao

Medical Physics · 2025-08 · 52 (8)

DOI: 10.1002/mp.18046 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 13.08.2025. Verfasst von Ying Luo und 10 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Algorithms, Proton Therapy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: the NIH, KUCC, physicist-scientist recruiting grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Treatment planning in proton therapy aims to deliver a conformal dose to the target while sparing normal healthy tissues. However, the range uncertainty of CT values and patient motion during delivery may compromise both target dose coverage and organ‐at‐risk (OAR) sparing.

Purpose

This study proposes a novel optimization method, Regularized‐Multi‐Field Optimization (R‐MFO). R‐MFO which incorporates the single‐field uniform dose as a regularization term in the multi‐field optimization (MFO). The proposed method seeks to reduce the sensitivity to uncertainties while maintaining the high plan quality as MFO plans.

Methods

R‐MFO combines the uniform dose distribution with the flexibility of MFO plans through an iterative process. Specifically, a dose equality constraint in the target volume for each field is introduced as a regularized term in the conventional MFO at every certain iteration. Robust optimization is performed with the range uncertainty of 3.5% and setup uncertainty of 3mm for the head and neck (HN) case and 5mm for the liver and lung cases. Due to the nonconvex constraints associated with minimum monitor unit (MMU) and active set, R‐MFO optimization is solved by iterative convex relaxation (ICR) and alternating direction method of multipliers (ADMM) algorithms. To demonstrate the effectiveness of our proposed R‐MFO, plan quality and robustness are compared with R‐MFO, MFO, and single‐field optimizations (SFO) across three clinical cases: HN, liver, and lung.

Results

R‐MFO demonstrated significantly enhanced robustness compared to MFO, with narrower uncertainty bands (e.g., RV 95 : 7.8–10.0 vs. 9.6–10.5) and superior high‐dose tail performance, though slightly inferior to SFO in RV 100 (26.2–31.5 vs. 19.2–26.9). Plan quality analysis revealed R‐MFO achieved higher conformity indices (CI: 0.65–0.79) and improved dose coverage (D 95 ≥99.15%, D max ≤111.90%) compared to SFO, approaching MFO performance. For OARs, both MFO and R‐MFO reduced esophageal D max , D mean , and D 5cc in the lung case by leveraging dose distribution flexibility. However, R‐MFO incurred the longest computational time due to comprehensive voxel‐level optimization, whereas MFO remained the most time‐efficient.

Conclusions

The proposed R‐MFO method successfully integrates the uniform dose characteristics of SFO with the flexibility of MFO, achieving enhanced robustness compared to MFO and superior plan quality compared to SFO.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedAlgorithmsProton TherapyHumansRadiotherapy DosageOrgans at RiskHead and Neck NeoplasmsUncertaintyLung NeoplasmsRadiotherapy, Intensity-Modulated

Stichwörter der Autor:innen

Alternative direction multiplier methodintensity modulated proton therapysingle‐field uniform dose

Autor:innen und Institutionen

  • Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China.
  • University of Chinese Academy of Sciences, Beijing, China.
  • Department of Radiation Oncology, University of Kansas Medical Center, Kansas City, Kansas, USA.

Förderung

  • the NIH
  • KUCC
  • physicist-scientist recruiting grant

Zitieren

APA

Luo, Y., Wang, C., Zhu, Y. N., Li, W., Johnson, D., Lin, Y., Akhavan, D., Reddy, K., Savioz, C., Li, Q., & Gao, H. (2025). A regularized‐multi‐field optimization algorithm for robust IMPT. Medical Physics, 52(8). https://doi.org/10.1002/mp.18046

Vancouver

Luo Y, Wang C, Zhu YN, Li W, Johnson D, Lin Y, et al. A regularized‐multi‐field optimization algorithm for robust IMPT. Medical Physics. 2025;52(8). doi:10.1002/mp.18046

BibTeX
@article{Luo2025,
  author = {Luo, Ying and Wang, Chao and Zhu, Ya-Nan and Li, Wangyao and Johnson, Daniel and Lin, Yuting and Akhavan, David and Reddy, Krishna and Savioz, Carolyn and Li, Qiang and Gao, Hao},
  title = {A regularized‐multi‐field optimization algorithm for robust IMPT},
  journal = {Medical Physics},
  year = {2025},
  volume = {52},
  number = {8},
  doi = {10.1002/mp.18046}
}
Kostenlos starten →