Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy
Physics in Medicine & Biology · 2023
DOI: 10.1088/1361-6560/acd433 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2023. Verfasst von Arthur Lalonde und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, United States of America. Hauptthemen laut MEDLINE: Proton Therapy, Head and Neck Neoplasms, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIGMS NIH HHS, NCI NIH HHS, Fonds de recherche du Québec – Nature et technologies.
Abstract (Originalsprache)
Objective . To evaluate the impact of setup uncertainty reduction (SUR) and adaptation to geometrical changes (AGC) on normal tissue complication probability (NTCP) when using online adaptive head and neck intensity modulated proton therapy (IMPT). Approach. A cohort of ten retrospective head and neck cancer patients with daily scatter corrected cone-beam CT (CBCT) was studied. For each patient, two IMPT treatment plans were created: one with a 3 mm setup uncertainty robustness setting and one with no explicit setup robustness. Both plans were recalculated on the daily CBCT considering three scenarios: the robust plan without adaptation, the non-robust plan without adaptation and the non-robust plan with daily online adaptation. Online-adaptation was simulated using an in-house developed workflow based on GPU-accelerated Monte Carlo dose calculation and partial spot-intensity re-optimization. Dose distributions associated with each scenario were accumulated on the planning CT, where NTCP models for six toxicities were applied. NTCP values from each scenario were intercompared to quantify the reduction in toxicity risk induced by SUR alone, AGC alone and SUR and AGC combined. Finally, a decision tree was implemented to assess the clinical significance of the toxicity reduction associated with each mechanism. Main results . For most patients, clinically meaningful NTCP reductions were only achieved when SUR and AGC were performed together. In these conditions, total reductions in NTCP of up to 30.48 pp were obtained, with noticeable NTCP reductions for aspiration, dysphagia and xerostomia (mean reductions of 8.25, 5.42 and 5.12 pp respectively). While SUR had a generally larger impact than AGC on NTCP reductions, SUR alone did not induce clinically meaningful toxicity reductions in any patient, compared to only one for AGC alone. Significance Online adaptive head and neck proton therapy can only yield clinically significant reductions in the risk of long-term side effects when combining the benefits of SUR and AGC.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, United States of America.
- ETH Zürich, Zürich, Switzerland.
ORCID-Profile: Arthur Lalonde, Mislav Bobić, Ibrahim Chamseddine, Brian Winey
Förderung
- NIGMS NIH HHS
- NCI NIH HHS
- Fonds de recherche du Québec – Nature et technologies
- Natural Sciences and Engineering Research Council of Canada
- National Cancer Institute
Zitieren
APA
Lalonde, A., Bobić, M., Sharp, G. C., Chamseddine, I., Winey, B., & Paganetti, H. (2023). Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/acd433
Vancouver
Lalonde A, Bobić M, Sharp GC, Chamseddine I, Winey B, Paganetti H. Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy. Physics in Medicine & Biology. 2023. doi:10.1088/1361-6560/acd433
BibTeX
@article{Lalonde2023,
author = {Lalonde, Arthur and Bobić, Mislav and Sharp, Gregory C and Chamseddine, Ibrahim and Winey, Brian and Paganetti, Harald},
title = {Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy},
journal = {Physics in Medicine & Biology},
year = {2023},
doi = {10.1088/1361-6560/acd433}
}
EUVIMED