EUVIMEDScopri EUVIMED
Crossref

Generative evidential synthesis with integrated segmentation framework for MR‐only radiation therapy treatment planning

Lina Mekki, Matthew Ladra, Sahaja Acharya, Junghoon Lee

Medical Physics · 2025

DOI: 10.1002/mp.17828 ↗

At a glance

Journal article in Medical Physics, 2025. Written by Lina Mekki and 3 co-authors. Institution: Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA. Major MEDLINE topics: Radiotherapy Planning, Computer-Assisted, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Cited 1 times so far (Crossref); 40 references. Funded by: Clark Fund for pediatric cancer research.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Radiation therapy (RT) planning is a time‐consuming process involving the contouring of target volumes and organs at risk, followed by treatment plan optimization. CT is typically used as the primary planning image modality as it provides electron density information needed for dose calculation. MRI is widely used for contouring after registration to CT due to its high soft tissue contrast. However, there exists uncertainties in registration, which propagate throughout treatment planning as contouring errors, and lead to dose inaccuracies. MR‐only RT planning has been proposed as a solution to eliminate the need for CT scan and image registration, by synthesizing CT from MRI. A challenge in deploying MR‐only planning in clinic is the lack of a method to estimate the reliability of a synthetic CT in the absence of ground truth. While methods have used sampling‐based approaches to estimate model uncertainty over multiple inferences, such methods suffer from long run time and are therefore inconvenient for clinical use.

Purpose

To develop a fast and robust method for the joint synthesis of CT from MRI, estimation of model uncertainty related to the synthesis accuracy, and segmentation of organs at risk (OARs), in a single model inference.

Methods

In this work, deep evidential regression is applied to MR‐only brain RT planning. The proposed framework uses a multi‐task vision transformer combining a single joint nested encoder with two distinct convolutional decoder paths for synthesis and segmentation separately. An evidential layer was added at the end of the synthesis decoder to jointly estimate model uncertainty in a single inference. The framework was trained and tested on a dataset of 119 (80 for training, 9 for validation, and 30 for test) paired T1‐weighted MRI and CT scans with OARs contours.

Results

The proposed method achieved mean ± SD SSIM of 0.820 ± 0.039, MAE of 47.4 ± 8.49 HU, and PSNR of 23.4 ± 1.13 for the synthesis task and dice similarity coefficient of 0.799 ± 0.132 (lenses), 0.945 ± 0.020 (eyes), 0.834 ± 0.059 (optic nerves), 0.679 ± 0.148 (chiasm), 0.947 ± 0.014 (temporal lobes), 0.849 ± 0.027 (hippocampus), 0.953 ± 0.024 (brainstem), 0.752 ± 0.228 (cochleae) for segmentation—in a total run time of 6.71 ± 0.25 s. Additionally, experiments on challenging test cases revealed that the proposed evidential uncertainty estimation highlighted the same uncertain regions as Monte Carlo‐based epistemic uncertainty, thus highlighting the reliability of the proposed method.

Conclusion

A framework leveraging deep evidential regression to jointly synthesize CT from MRI, predict the related synthesis uncertainty, and segment OARs in a single model inference was developed. The proposed approach has the potential to streamline the planning process and provide clinicians with a measure of the reliability of a synthetic CT in the absence of ground truth.

Subjects

MeSH terms (MEDLINE)

Radiotherapy Planning, Computer-AssistedMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansTomography, X-Ray ComputedOrgans at Risk

Author keywords

MR‐only radiotherapy planningbrain radiotherapyevidential deep learningjoint synthesis and segmentation

Authors and institutions

  • Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA.
  • Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland, USA.

Funding

  • Clark Fund for pediatric cancer research

Cite

APA

Mekki, L., Ladra, M., Acharya, S., & Lee, J. (2025). Generative evidential synthesis with integrated segmentation framework for MR‐only radiation therapy treatment planning. Medical Physics. https://doi.org/10.1002/mp.17828

Vancouver

Mekki L, Ladra M, Acharya S, Lee J. Generative evidential synthesis with integrated segmentation framework for MR‐only radiation therapy treatment planning. Medical Physics. 2025. doi:10.1002/mp.17828

BibTeX
@article{Mekki2025,
  author = {Mekki, Lina and Ladra, Matthew and Acharya, Sahaja and Lee, Junghoon},
  title = {Generative evidential synthesis with integrated segmentation framework for MR‐only radiation therapy treatment planning},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17828}
}
Start for free →