EUVIMEDObjevte EUVIMED
Open access · CC BY-NC 4.0

Estimation of the relative biological effectiveness for double strand break induction of clinical kilovoltage beams using Monte Carlo simulations

Oran McElligott, Mihails Nikandrovs, Patrick McCavana, Brendan McClean, Luis León Vintró

Medical Physics · 2024

DOI: 10.1002/mp.17060 ↗

At a glance

Journal article in Medical Physics, 2024. Written by Oran McElligott and 4 co-authors. Institution: School of Physics, University College Dublin, Dublin, Ireland. Major MEDLINE topics: Monte Carlo Method, Relative Biological Effectiveness, DNA Breaks, Double-Stranded. Cited 3 times so far (Crossref); 36 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: National Cancer Control Programe of the HSE, Ireland.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

The Relative Biological Effectiveness (RBE) of kilovoltage photon beams has been previously investigated in vitro and in silico using analytical methods. The estimated values range from 1.03 to 1.82 depending on the methodology and beam energies examined.

Purpose

The focus of this work was to independently estimate RBE values for a range of clinically used kilovoltage beams (70–200 kVp) while investigating the suitability of using TOPAS‐nBio for this task.

Methods

Previously validated spectra of clinical beams were used to generate secondary electron spectra at several depths in a water tank phantom via TOPAS Monte Carlo (MC) simulations. Cell geometry was irradiated with the secondary electrons in TOPAS‐nBio MC simulations. The deposited dose and the calculated number of DNA strand breaks were used to estimate RBE values.

Results

Monoenergetic secondary electron simulations revealed the highest direct and indirect double strand break yield at approximately 20 keV. The average RBE value for the kilovoltage beams was calculated to be 1.14.

Conclusions

TOPAS‐nBio was successfully used to estimate the RBE values for a range of clinical radiotherapy beams. The calculated value was in agreement with previous estimates, providing confidence in its clinical use in the future.

Subjects

MeSH terms (MEDLINE)

Monte Carlo MethodRelative Biological EffectivenessDNA Breaks, Double-StrandedHumansElectronsRadiotherapy DosagePhotonsComputer SimulationPhantoms, Imaging

Author keywords

TOPAS‐nBiokilovoltagerelative biological effectiveness

Authors and institutions

  • School of Physics, University College Dublin, Dublin, Ireland.
  • St. Lukes Radiation Oncology Network, Dublin, Ireland.
  • Centre for Physics in Health and Medicine, University College Dublin, Dublin, Ireland.

Funding

  • National Cancer Control Programe of the HSE, Ireland

Cite

APA

McElligott, O., Nikandrovs, M., McCavana, P., McClean, B., & León Vintró, L. (2024). Estimation of the relative biological effectiveness for double strand break induction of clinical kilovoltage beams using Monte Carlo simulations. Medical Physics. https://doi.org/10.1002/mp.17060

Vancouver

McElligott O, Nikandrovs M, McCavana P, McClean B, León Vintró L. Estimation of the relative biological effectiveness for double strand break induction of clinical kilovoltage beams using Monte Carlo simulations. Medical Physics. 2024. doi:10.1002/mp.17060

BibTeX
@article{McElligott2024,
  author = {McElligott, Oran and Nikandrovs, Mihails and McCavana, Patrick and McClean, Brendan and León Vintró, Luis},
  title = {Estimation of the relative biological effectiveness for double strand break induction of clinical kilovoltage beams using Monte Carlo simulations},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.17060}
}
Start for free →