EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Generation and evaluation of anatomy‐preserving virtual CT for online adaptive proton therapy

Suryakant Kaushik, Jakob Ödén, Dayananda Shamurailatpam Sharma, Albin Fredriksson, Iuliana Toma-Dasu

Medical Physics · 2024-03 · 51 (3) · 1536-1546

DOI: 10.1002/mp.16941 ↗

At a glance

Journal article in Medical Physics, published online on 2024-01-17. Written by Suryakant Kaushik and 4 co-authors. Institution: RaySearch Laboratories AB (Publ), Stockholm, Sweden. Major MEDLINE topics: Proton Therapy, Head and Neck Neoplasms, Radiotherapy, Intensity-Modulated. Cited 12 times so far (Crossref); 35 references. The full text is freely available (open access, CC BY 4.0). Funded by: European Union's Horizon 2020 Marie Skłodowska-Curie Actions.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Daily CTs generated by CBCT correction are required for daily replanning in online‐adaptive proton therapy (APT) to effectively deal with inter‐fractional changes. Out of the currently available methods, the suitability of a daily CT generation method for proton dose calculation also depends on the anatomical site.

Purpose

We propose an anatomy‐preserving virtual CT (APvCT) method as a hybrid method of CBCT correction, which is especially suitable for large anatomy deformations. The accuracy of the hybrid method was assessed by comparison with the corrected CBCT (cCBCT) and virtual CT (vCT) methods in the context of online APT.

Methods

Seventy‐one daily CBCTs of four prostate cancer patients treated with intensity modulated proton therapy (IMPT) were converted to daily CTs using cCBCT, vCT, and the newly proposed APvCT method. In APvCT, planning CT (pCT) were mapped to CBCT geometry using deformable image registration with boundary conditions on controlling regions of interest (ROIs) created with deep learning segmentation on cCBCT. The relative frequency distribution (RFD) of HU, mass density and stopping power ratio (SPR) values were assessed and compared with the pCT. The ROIs in the APvCT and vCT were compared with cCBCT in terms of Dice similarity coefficient (DSC) and mean distance‐to‐agreement (mDTA). For each patient, a robustly optimized IMPT plan was created on the pCT and subsequent daily adaptive plans on daily CTs. For dose distribution comparison on the same anatomy, the daily adaptive plans on cCBCT and vCT were recalculated on the corresponding APvCT. The dose distributions were compared in terms of isodose volumes and 3D global gamma‐index passing rate (GPR) at γ(2%, 2 mm) criterion.

Results

For all patients, no noticeable difference in RFDs was observed amongst APvCT, vCT, and pCT except in cCBCT, which showed a noticeable difference. The minimum DSC value was 0.96 and 0.39 for contours in APvCT and vCT respectively. The average value of mDTA for APvCT was 0.01 cm for clinical target volume and ≤0.01 cm for organs at risk, which increased to 0.18 cm and ≤0.52 cm for vCT. The mean GPR value was 90.9%, 64.5%, and 67.0% for APvCT versus cCBCT, vCT versus cCBCT, and APvCT versus vCT, respectively. When recalculated on APvCT, the adaptive cCBCT and vCT plans resulted in mean GPRs of 89.5 ± 5.1% and 65.9 ± 19.1%, respectively. The mean DSC values for 80.0%, 90.0%, 95.0%, 98.0%, and 100.0% isodose volumes were 0.97, 0.97, 0.97, 0.95, and 0.91 for recalculated cCBCT plans, and 0.89, 0.88, 0.87, 0.85, and 0.81 for recalculated vCT plans. Hausdorff distance for the 100.0% isodose volume in some cases of recalculated cCBCT plans on APvCT exceeded 1.00 cm.

Conclusions

APvCT contours showed good agreement with reference contours of cCBCT which indicates anatomy preservation in APvCT. A vCT with erroneous anatomy can result in an incorrect adaptive plan. Further, slightly lower values of GPR between the APvCT and cCBCT‐based adaptive plans can be explained by the difference in the cCBCT's SPR RFD from the pCT.

Subjects

MeSH terms (MEDLINE)

Proton TherapyHead and Neck NeoplasmsRadiotherapy, Intensity-ModulatedMaleHumansRadiotherapy DosageCone-Beam Computed TomographyRadiotherapy Planning, Computer-AssistedImage Processing, Computer-Assisted

Author keywords

adaptive proton therapyvirtual/synthetic CT | daily anatomical variation

Authors and institutions

  • RaySearch Laboratories AB (Publ), Stockholm, Sweden.
  • Department of Physics, Medical Radiation Physics, Stockholm University, Stockholm, Sweden.
  • Department of Oncology and Pathology, Medical Radiation Physics, Karolinska Institutet, Stockholm, Sweden.
  • Department of Medical Physics, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India.

Funding

  • European Union's Horizon 2020 Marie Skłodowska-Curie Actions

Cite

APA

Kaushik, S., Ödén, J., Sharma, D. S., Fredriksson, A., & Toma-Dasu, I. (2024). Generation and evaluation of anatomy‐preserving virtual CT for online adaptive proton therapy. Medical Physics, 51(3), 1536-1546. https://doi.org/10.1002/mp.16941

Vancouver

Kaushik S, Ödén J, Sharma DS, Fredriksson A, Toma-Dasu I. Generation and evaluation of anatomy‐preserving virtual CT for online adaptive proton therapy. Medical Physics. 2024;51(3):1536-1546. doi:10.1002/mp.16941

BibTeX
@article{Kaushik2024,
  author = {Kaushik, Suryakant and Ödén, Jakob and Sharma, Dayananda Shamurailatpam and Fredriksson, Albin and Toma-Dasu, Iuliana},
  title = {Generation and evaluation of anatomy‐preserving virtual CT for online adaptive proton therapy},
  journal = {Medical Physics},
  year = {2024},
  volume = {51},
  number = {3},
  pages = {1536--1546},
  doi = {10.1002/mp.16941}
}
Start for free →