Streamlined pin‐ridge‐filter design for single‐energy proton FLASH planning

Chaoqiong Ma, Jun Zhou, Chih-Wei Chang, Yinan Wang, Pretesh R Patel, David S Yu, Sibo Tian, Xiaofeng Yang

Medical Physics · 2024-04 · 51 (4) · 2955-2966

DOI: 10.1002/mp.16939 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 12.01.2024. Verfasst von Chaoqiong Ma und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Neoplasms, Radiotherapy, Intensity-Modulated, Proton Therapy. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Cancer Institute of the National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

FLASH radiotherapy (FLASH‐RT) with ultra‐high dose rate has yielded promising results in reducing normal tissue toxicity while maintaining tumor control. Planning with single‐energy proton beams modulated by ridge filters (RFs) has been demonstrated feasible for FLASH‐RT.

Purpose

This study explored the feasibility of a streamlined pin‐shaped RF (pin‐RF) design, characterized by coarse resolution and sparsely distributed ridge pins, for single‐energy proton FLASH planning.

Methods

An inverse planning framework integrated within a treatment planning system was established to design streamlined pin RFs for single‐energy FLASH planning. The framework involves generating a multi‐energy proton beam plan using intensity‐modulated proton therapy (IMPT) planning based on downstream energy modulation strategy (IMPT‐DS), followed by a nested pencil‐beam‐direction‐based (PBD‐based) spot reduction process to iteratively reduce the total number of PBDs and energy layers along each PBD for the IMPT‐DS plan. The IMPT‐DS plan is then translated into the pin‐RFs and the single‐energy beam configurations for IMPT planning with pin‐RFs (IMPT‐RF). This framework was validated on three lung cases, quantifying the FLASH dose of the IMPT‐RF plan using the FLASH effectiveness model. The FLASH dose was then compared to the reference dose of a conventional IMPT plan to measure the clinical benefit of the FLASH planning technique.

Results

The IMPT‐RF plans closely matched the corresponding IMPT‐DS plans in high dose conformity (conformity index of

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeoplasmsRadiotherapy, Intensity-ModulatedProton TherapyHumansProtonsRadiotherapy Planning, Computer-AssistedRadiotherapy DosageOrgans at Risk

Stichwörter der Autor:innen

proton FLASHsingle‐energy planningstreamlined ridge filter

Substanzen

Protons

Autor:innen und Institutionen

  • Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.

Förderung

  • National Cancer Institute of the National Institutes of Health

Zitieren

APA

Ma, C., Zhou, J., Chang, C. W., Wang, Y., Patel, P. R., Yu, D. S., Tian, S., & Yang, X. (2024). Streamlined pin‐ridge‐filter design for single‐energy proton FLASH planning. Medical Physics, 51(4), 2955-2966. https://doi.org/10.1002/mp.16939

Vancouver

Ma C, Zhou J, Chang CW, Wang Y, Patel PR, Yu DS, et al. Streamlined pin‐ridge‐filter design for single‐energy proton FLASH planning. Medical Physics. 2024;51(4):2955-2966. doi:10.1002/mp.16939

BibTeX
@article{Ma2024,
  author = {Ma, Chaoqiong and Zhou, Jun and Chang, Chih-Wei and Wang, Yinan and Patel, Pretesh R and Yu, David S and Tian, Sibo and Yang, Xiaofeng},
  title = {Streamlined pin‐ridge‐filter design for single‐energy proton FLASH planning},
  journal = {Medical Physics},
  year = {2024},
  volume = {51},
  number = {4},
  pages = {2955--2966},
  doi = {10.1002/mp.16939}
}