EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Intensity modulated proton arc therapy via geometry‐based energy selection for ependymoma

Wenhua Cao iD, Yupeng Li, Xiaodong Zhang, Falk Poenisch, Pablo Yepes, Narayan Sahoo iD, David Grosshans, Susan McGovern, G Brandon Gunn, Steven J Frank, Xiaorong R Zhu

Journal of Applied Clinical Medical Physics · 2023

DOI: 10.1002/acm2.13954 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2023. Verfasst von Wenhua Cao und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA. Hauptthemen laut MEDLINE: Proton Therapy, Ependymoma, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, National Institutes of Health (NIH).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

We developed and tested a novel method of creating intensity modulated proton arc therapy (IMPAT) plans that uses computing resources similar to those for regular intensity‐modulated proton therapy (IMPT) plans and may offer a dosimetric benefit for patients with ependymoma or similar tumor geometries.

Methods

Our IMPAT planning method consists of a geometry‐based energy selection step with major scanning spot contributions as inputs computed using ray‐tracing and single‐Gaussian approximation of lateral spot profiles. Based on the geometric relation of scanning spots and dose voxels, our energy selection module selects a minimum set of energy layers at each gantry angle such that each target voxel is covered by sufficient scanning spots as specified by the planner, with dose contributions above the specified threshold. Finally, IMPAT plans are generated by robustly optimizing scanning spots of the selected energy layers using a commercial proton treatment planning system (TPS). The IMPAT plan quality was assessed for four ependymoma patients. Reference three‐field IMPT plans were created with similar planning objective functions and compared with the IMPAT plans.

Results

In all plans, the prescribed dose covered 95% of the clinical target volume (CTV) while maintaining similar maximum doses for the brainstem. While IMPAT and IMPT achieved comparable plan robustness, the IMPAT plans achieved better homogeneity and conformity than the IMPT plans. The IMPAT plans also exhibited higher relative biological effectiveness (RBE) enhancement than did the corresponding reference IMPT plans for the CTV in all four patients and brainstem in three of them.

Conclusions

The proposed method demonstrated potential as an efficient technique for IMPAT planning and may offer a dosimetric benefit for patients with ependymoma or tumors in close proximity to critical organs. IMPAT plans created using this method had elevated RBE enhancement associated with increased linear energy transfer (LET) in both targets and abutting critical organs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyEpendymomaRadiotherapy, Intensity-ModulatedHumansProtonsRadiotherapy DosageRadiotherapy Planning, Computer-AssistedOrgans at Risk

Stichwörter der Autor:innen

Proton Arc Geometry-based Ependymoma

Substanzen

Protons

Autor:innen und Institutionen

  • Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Department of Physics and Astronomy, Rice University, Houston, Texas, USA.
  • Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.

ORCID-Profile: Wenhua Cao, Narayan Sahoo

Förderung

  • NCI NIH HHS
  • National Institutes of Health (NIH)

Zitieren

APA

Cao, W., Li, Y., Zhang, X., Poenisch, F., Yepes, P., Sahoo, N., Grosshans, D., McGovern, S., Gunn, G. B., Frank, S. J., & Zhu, X. R. (2023). Intensity modulated proton arc therapy via geometry‐based energy selection for ependymoma. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.13954

Vancouver

Cao W, Li Y, Zhang X, Poenisch F, Yepes P, Sahoo N, et al. Intensity modulated proton arc therapy via geometry‐based energy selection for ependymoma. Journal of Applied Clinical Medical Physics. 2023. doi:10.1002/acm2.13954

BibTeX
@article{Cao2023,
  author = {Cao, Wenhua and Li, Yupeng and Zhang, Xiaodong and Poenisch, Falk and Yepes, Pablo and Sahoo, Narayan and Grosshans, David and McGovern, Susan and Gunn, G Brandon and Frank, Steven J and Zhu, Xiaorong R},
  title = {Intensity modulated proton arc therapy via geometry‐based energy selection for ependymoma},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2023},
  doi = {10.1002/acm2.13954}
}
Kostenlos starten →