EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automated treatment planning for proton pencil beam scanning using deep learning dose prediction and dose‐mimicking optimization

Dominic Maes iD, Mats Holmstrom, Rasmus Helander, Jatinder Saini, Christine Fang, Stephen R Bowen iD

Journal of Applied Clinical Medical Physics · 2023

DOI: 10.1002/acm2.14065 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2023. Verfasst von Dominic Maes und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Washington School of Medicine, Seattle, Washington, USA. Hauptthemen laut MEDLINE: Deep Learning, Proton Therapy, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study is to investigate the use of a deep learning architecture for automated treatment planning for proton pencil beam scanning (PBS).

Methods

A 3‐dimensional (3D) U‐Net model has been implemented in a commercial treatment planning system (TPS) that uses contoured regions of interest (ROI) binary masks as model inputs with a predicted dose distribution as the model output. Predicted dose distributions were converted to deliverable PBS treatment plans using a voxel‐wise robust dose mimicking optimization algorithm. This model was leveraged to generate machine learning (ML) optimized plans for patients receiving proton PBS irradiation of the chest wall. Model training was carried out on a retrospective set of 48 previously‐treated chest wall patient treatment plans. Model evaluation was carried out by generating ML‐optimized plans on a hold‐out set of 12 contoured chest wall patient CT datasets from previously treated patients. Clinical goal criteria and gamma analysis were used to compare dose distributions of the ML‐optimized plans against the clinically approved plans across the test patients.

Results

Statistical analysis of mean clinical goal criteria indicates that compared to the clinical plans, the ML optimization workflow generated robust plans with similar dose to the heart, lungs, and esophagus while achieving superior dosimetric coverage to the PTV chest wall (clinical mean V95 = 97.6% vs. ML mean V95 = 99.1%, p < 0.001) across the 12 test patients.

Conclusions

ML‐based automated treatment plan optimization using the 3D U‐Net model can generate treatment plans of similar clinical quality compared to human‐driven optimization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningProton TherapyRadiotherapy, Intensity-ModulatedHumansProtonsRetrospective StudiesRadiotherapy Planning, Computer-AssistedRadiotherapy DosageOrgans at Risk

Stichwörter der Autor:innen

deep learningproton therapy

Substanzen

Protons

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Washington School of Medicine, Seattle, Washington, USA.
  • Raysearch Laboratories, Stockholm, Sweden.
  • Department of Radiology, University of Washington School of Medicine, Seattle, Washington, USA.

ORCID-Profile: Dominic Maes, Stephen R Bowen

Zitieren

APA

Maes, D., Holmstrom, M., Helander, R., Saini, J., Fang, C., & Bowen, S. R. (2023). Automated treatment planning for proton pencil beam scanning using deep learning dose prediction and dose‐mimicking optimization. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14065

Vancouver

Maes D, Holmstrom M, Helander R, Saini J, Fang C, Bowen SR. Automated treatment planning for proton pencil beam scanning using deep learning dose prediction and dose‐mimicking optimization. Journal of Applied Clinical Medical Physics. 2023. doi:10.1002/acm2.14065

BibTeX
@article{Maes2023,
  author = {Maes, Dominic and Holmstrom, Mats and Helander, Rasmus and Saini, Jatinder and Fang, Christine and Bowen, Stephen R},
  title = {Automated treatment planning for proton pencil beam scanning using deep learning dose prediction and dose‐mimicking optimization},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2023},
  doi = {10.1002/acm2.14065}
}
Kostenlos starten →