EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High‐resolution three‐dimensional dosimetry in clinically relevant volumes utilizing optically stimulated luminescence

Mads L Jensen iD, Brian Julsgaard iD, Rosana M Turtos iD, Peter S Skyt iD, Morten B Jensen iD, Ludvig P Muren iD, Peter Balling iD

Medical Physics · 2024

DOI: 10.1002/mp.16796 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Mads L Jensen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark. Hauptthemen laut MEDLINE: Luminescence, Optically Stimulated Luminescence Dosimetry. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Novo Nordisk Fonden.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The continued development of new radiotherapy techniques requires dosimetry systems that satisfy increasingly rigorous requirements, such as high sensitivity, wide dose range, and high spatial resolution. An emerging requirement is the ability to read out doses in three dimensions (3D) with high precision and spatial resolution. A few dosimetry systems with 3D capabilities are available, but their application in a clinical workflow is limited for various reasons, primarily originating from their chemical nature. The search for a 3D dosimetry system with potential for clinical implementation is thus ongoing.

Purpose

To demonstrate the capabilities of a novel optically‐stimulated‐luminescence (OSL)‐based 3D dosimetry system capable of measuring radiation doses in clinically relevant volumes.

Methods

A laser‐based readout system was used to measure dose distributions delivered by both photons and protons, utilizing the OSL from a mm YSO:Ce crystal. A homogeneous treatment plan consisting of two opposing photon fields was used to establish an inhomogeneity correction map of the crystal response and demonstrated the accuracy and precision of the system. The crystal was additionally irradiated with a photon treatment plan consisting of three overlapping mm fields delivered from different angles, and a proton treatment plan consisting of four pencil beams with energies 90 MeV (), 115 MeV, and 140 MeV. The system abilities were quantified by comparing the 3D‐resolved measurements to Monte Carlo simulations.

Results

The dose map reproducibility of the system was found to be within 2% including both statistical and systematic errors. The measurements yielded integrated doses from a volume of mm with voxel volumes of just mm . An excellent agreement between the 3D‐resolved measurements and the simulations was found for both photon‐ and proton‐irradiation.

Conclusions

The capabilities of the devised system for measuring clinically relevant fields of photons and proton pencil beams within a clinically relevant volume were demonstrated. The system poses as a promising candidate for clinical applications, and enables future research in the field of OSL‐based tissue‐equivalent 3D dosimetry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LuminescenceOptically Stimulated Luminescence DosimetryProtonsReproducibility of ResultsRadiometry

Stichwörter der Autor:innen

3D dosimetryOSLProton therapyRadiotherapy

Substanzen

Protons

Autor:innen und Institutionen

  • Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark.
  • Interdisciplinary Nanoscience Center, Aarhus University, Aarhus, Denmark.
  • Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
  • Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark.
  • Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.

ORCID-Profile: Mads L Jensen, Brian Julsgaard, Rosana M Turtos, Peter S Skyt, Morten B Jensen, Ludvig P Muren, Peter Balling

Förderung

  • Novo Nordisk Fonden

Zitieren

APA

Jensen, M. L., Julsgaard, B., Turtos, R. M., Skyt, P. S., Jensen, M. B., Muren, L. P., & Balling, P. (2024). High‐resolution three‐dimensional dosimetry in clinically relevant volumes utilizing optically stimulated luminescence. Medical Physics. https://doi.org/10.1002/mp.16796

Vancouver

Jensen ML, Julsgaard B, Turtos RM, Skyt PS, Jensen MB, Muren LP, et al. High‐resolution three‐dimensional dosimetry in clinically relevant volumes utilizing optically stimulated luminescence. Medical Physics. 2024. doi:10.1002/mp.16796

BibTeX
@article{Jensen2024,
  author = {Jensen, Mads L and Julsgaard, Brian and Turtos, Rosana M and Skyt, Peter S and Jensen, Morten B and Muren, Ludvig P and Balling, Peter},
  title = {High‐resolution three‐dimensional dosimetry in clinically relevant volumes utilizing optically stimulated luminescence},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.16796}
}
Kostenlos starten →