EUVIMEDAvasta EUVIMED
Open access · CC BY-NC 4.0

Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model‐based dose calculations

Elizabeth M Fletcher, Facundo Ballester, Luc Beaulieu, Hali Morrison, Audran Poher, Mark J Rivard, Ron S Sloboda, Javier Vijande, Rowan M Thomson

Medical Physics · 2024

DOI: 10.1002/mp.16721 ↗

At a glance

Journal article in Medical Physics, 2024. Written by Elizabeth M Fletcher and 8 co-authors. Institution: Carleton Laboratory for Radiotherapy Physics, Physics Department, Carleton University, Ottawa, Ontario, Canada. Major MEDLINE topics: Brachytherapy, Melanoma, Eye Neoplasms. Cited 6 times so far (Crossref); 56 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Natural Sciences and Engineering Research Council of Canada, Canada Research Chairs, Carleton University Research Office.

AbstraktSubjectsBibliograafilised andmedCiteRelated studies

Abstract (original language)

Purpose A joint Working Group of the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) was created to aid in the transition from the AAPM TG‐43 dose calculation formalism, the current standard, to model‐based dose calculations. This work establishes the first test cases for low‐energy photon‐emitting brachytherapy using model‐based dose calculation algorithms (MBDCAs). Acquisition and Validation Methods Five test cases are developed: (1) a single model 6711 125 I brachytherapy seed in water, 13 seeds (2) individually and (3) in combination in water, (4) the full Collaborative Ocular Melanoma Study (COMS) 16 mm eye plaque in water, and (5) the full plaque in a realistic eye phantom. Calculations are done with four Monte Carlo (MC) codes and a research version of a commercial treatment planning system (TPS). For all test cases, local agreement of MC codes was within ∼2.5% and global agreement was ∼2% (4% for test case 5). MC agreement was within expected uncertainties. Local agreement of TPS with MC was within 5% for test case 1 and ∼20% for test cases 4 and 5, and global agreement was within 0.4% for test case 1 and 10% for test cases 4 and 5. Data Format and Usage Notes Dose distributions for each set of MC and TPS calculations are available online ( https://doi.org/10.52519/00005 ) along with input files and all other information necessary to repeat the calculations. Potential Applications These data can be used to support commissioning of MBDCAs for low‐energy brachytherapy as recommended by TGs 186 and 221 and AAPM Report 372. This work additionally lays out a sample framework for the development of test cases that can be extended to other applications beyond eye plaque brachytherapy.

Subjects

MeSH terms (MEDLINE)

BrachytherapyMelanomaEye NeoplasmsHumansRadiotherapy DosageRadiometryMonte Carlo MethodWaterRadiotherapy Planning, Computer-AssistedIodine Radioisotopes

Author keywords

Monte Carloocular brachytherapytreatment planning

Substances

WaterIodine-125Iodine Radioisotopes

Authors and institutions

  • Carleton Laboratory for Radiotherapy Physics, Physics Department, Carleton University, Ottawa, Ontario, Canada.
  • Departamento de Física Atómica, Molecular y Nuclear, Universitat de Valencia (UV), Burjassot, Spain.
  • Unidad Mixta de Investigación en Radiofísica e Instrumentación Nuclear en Medicina (IRIMED), Instituto de Investigación Sanitaria La Fe (IIS-La Fe)-Universitat de Valencia (UV), Burjassot, Spain.
  • Service de physique médicale et Axe oncologie du Centre de recherche du CHU de Québec, CHU de Québec, Québec, Québec, Canada.
  • Département de Physique, de Génie Physique et d'Optique et Centre de Recherche sur le Cancer, Université Laval, Québec, Québec, Canada.
  • Department of Oncology and Department of Physics and Astronomy, University of Calgary, Calgary, AB, Canada.

Funding

  • Natural Sciences and Engineering Research Council of Canada
  • Canada Research Chairs
  • Carleton University Research Office
  • Queen Elizabeth II Graduate Scholarship in Science and Technology
  • Ontario Graduate Scholarship
  • Ministerio de Ciencia e Innovación
  • Generalitat Valenciana.Conselleria de Innovación, Universidades, Ciencia y Sociedad Digital

Cite

APA

Fletcher, E. M., Ballester, F., Beaulieu, L., Morrison, H., Poher, A., Rivard, M. J., Sloboda, R. S., Vijande, J., & Thomson, R. M. (2024). Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model‐based dose calculations. Medical Physics. https://doi.org/10.1002/mp.16721

Vancouver

Fletcher EM, Ballester F, Beaulieu L, Morrison H, Poher A, Rivard MJ, et al. Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model‐based dose calculations. Medical Physics. 2024. doi:10.1002/mp.16721

BibTeX
@article{Fletcher2024,
  author = {Fletcher, Elizabeth M and Ballester, Facundo and Beaulieu, Luc and Morrison, Hali and Poher, Audran and Rivard, Mark J and Sloboda, Ron S and Vijande, Javier and Thomson, Rowan M},
  title = {Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model‐based dose calculations},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.16721}
}
Start for free →