Fachartikel in der Zeitschrift Brachytherapy, 2024. Verfasst von Yongsook C Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL; Department of Radiation Oncology, Herbert Wertheim…. Hauptthemen laut MEDLINE: Brachytherapy, Monte Carlo Method, Iodine Radioisotopes, Radiotherapy Dosage. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To provide a practical method of estimating medium-heterogeneity corrected dose without a Monte Carlo (MC) calculation in ocular brachytherapy using 125I Collaborative Ocular Melanoma Study (COMS) plaques. METHODS AND MATERIALS: Using egs_brachy, MC simulations (1) under task group-43 assumptions with fully loaded seed configurations in water (HOMO) and (2) with effects of plaque backing, insert and inter-seed interactions (HETERO) were performed for seven 125I COMS plaques (10 mm-22 mm in diameter), and homogeneous dose (DHOMO) and heterogeneous dose (DHETERO) for central-axis and off-axis points were determined. For DHOMO, 85 Gy was normalized to a depth of 5 mm. Central-axis heterogeneity correction factors (HCFs) from a depth of 0 mm (inner sclera) to 22 mm (opposite retina) were derived from a ratio of DHETERO to DHOMO. Off-axis HCFs for optic disc/macula and lens as a function of distance from optic disc/macula (DT/MT) for various basal dimensions of tumor (BD/BM) were derived from DHETERO/DHOMO. RESULTS: Central-axis HCF varied with a dose reduction of 10.3-19.8% by heterogeneity. Off-axis HCF for optic disc/macula varied significantly depending on DT/MT and BD/BM with a dose reduction of 11.3-38.3%. Off-axis HCF for lens had a dependence on MT and BM with its variation of 11.0-19.0%. A clinical example of using HCFs to estimate DHETERO was presented. CONCLUSIONS: The practical method of using depth-dependent central-axis HCF and DT/MT- and BD/BM-dependent off-axis HCF provided in this study will facilitate a heterogeneous dose estimate for 125I COMS plaques without MC calculations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyMonte Carlo MethodIodine RadioisotopesRadiotherapy DosageMelanomaEye NeoplasmsHumansRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

Collaborative ocular melanoma studyEgs_brachyHeterogeneity correction factorsHeterogeneous doseMonte CarloOcular brachytherapy

Substanzen

Iodine RadioisotopesIodine-125

Autor:innen und Institutionen

  • Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL; Department of Radiation Oncology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL.
  • Department of Physics, East Carolina University, Greenville, NC.
  • Department of Radiation Oncology, Duke University, Durham, NC. Electronic address: yongbok.kim@duke.edu.
  • Department of Radiation Oncology, East Carolina University, Greenville, NC.

Zitieren

APA

Lee, Y. C., Nik Akhtar, M., Kim, Y., & Jung, J. W. (2024). A practical method of estimating medium-heterogeneity corrected dose without a Monte Carlo calculation in ocular brachytherapy using 125I COMS plaques. Brachytherapy. https://doi.org/10.1016/j.brachy.2024.01.001

Vancouver

Lee YC, Nik Akhtar M, Kim Y, Jung JW. A practical method of estimating medium-heterogeneity corrected dose without a Monte Carlo calculation in ocular brachytherapy using 125I COMS plaques. Brachytherapy. 2024. doi:10.1016/j.brachy.2024.01.001

BibTeX
@article{Lee2024,
  author = {Lee, Yongsook C and Nik Akhtar, Mehran and Kim, Yongbok and Jung, Jae Won},
  title = {A practical method of estimating medium-heterogeneity corrected dose without a Monte Carlo calculation in ocular brachytherapy using 125I COMS plaques},
  journal = {Brachytherapy},
  year = {2024},
  doi = {10.1016/j.brachy.2024.01.001}
}
Kostenlos starten →