Image‐based scatter correction for cone‐beam CT using flip swin transformer U‐shape network
Medical Physics · 2023-08 · 50 (8) · 5002-5019
DOI: 10.1002/mp.16277 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 14.02.2023. Verfasst von Xueren Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Shandong Key Laboratory of Medical Physics and Image Processing, Shandong Institute of Industrial Technology for Health Sciences and Precision Medici…. Hauptthemen laut MEDLINE: Algorithms, Neural Networks, Computer. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: National Nature Science Foundation of China, Natural Science Foundation of Shandong Province, National Key R&D Program of China.
Abstract (Originalsprache)
Background
Cone beam computed tomography (CBCT) plays an increasingly important role in image‐guided radiation therapy. However, the image quality of CBCT is severely degraded by excessive scatter contamination, especially in the abdominal region, hindering its further applications in radiation therapy.
Purpose
To restore low‐quality CBCT images contaminated by scatter signals, a scatter correction algorithm combining the advantages of convolutional neural networks (CNN) and Swin Transformer is proposed.
Methods
In this paper a scatter correction model for CBCT image, the Flip Swin Transformer U‐shape network (FSTUNet) model, is proposed. In this model, the advantages of CNN in texture detail and Swin Transformer in global correlation are used to accurately extract shallow and deep features, respectively. Instead of using the original Swin Transformer tandem structure, we build the Flip Swin Transformer Block to achieve a more powerful inter‐window association extraction. The validity and clinical relevance of the method is demonstrated through extensive experiments on a Monte Carlo (MC) simulation dataset and frequency split dataset generated by a validated method, respectively.
Result
Experimental results on the MC simulated dataset show that the root mean square error of images corrected by the method is reduced from over 100 HU to about 7 HU. Both the structural similarity index measure (SSIM) and the universal quality index (UQI) are close to 1. Experimental results on the frequency split dataset demonstrate that the method not only corrects shading artifacts but also exhibits a high degree of structural consistency. In addition, comparison experiments show that FSTUNet outperforms UNet, Deep Residual Convolutional Neural Network (DRCNN), DSENet, Pix2pixGAN, and 3DUnet methods in both qualitative and quantitative metrics.
Conclusions
Accurately capturing the features at different levels is greatly beneficial for reconstructing high‐quality scatter‐free images. The proposed FSTUNet method is an effective solution to CBCT scatter correction and has the potential to improve the accuracy of CBCT image‐guided radiation therapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Shandong Key Laboratory of Medical Physics and Image Processing, Shandong Institute of Industrial Technology for Health Sciences and Precision Medicine, School of Physics and Electronics, Shandong Normal University, Jin…
- Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Institute of Translational Medicine, Zhejiang University, Hangzhou, Zhejiang, China.
- Shenzhen Bay Laboratory, Shenzhen, China.
- School of Automation, Zhejiang Institute of Mechanical & Electrical Engineering, Hangzhou, China.
Förderung
- National Nature Science Foundation of China
- Natural Science Foundation of Shandong Province
- National Key R&D Program of China
Zitieren
APA
Zhang, X., Jiang, Y., Luo, C., Li, D., Niu, T., & Yu, G. (2023). Image‐based scatter correction for cone‐beam CT using flip swin transformer U‐shape network. Medical Physics, 50(8), 5002-5019. https://doi.org/10.1002/mp.16277
Vancouver
Zhang X, Jiang Y, Luo C, Li D, Niu T, Yu G. Image‐based scatter correction for cone‐beam CT using flip swin transformer U‐shape network. Medical Physics. 2023;50(8):5002-5019. doi:10.1002/mp.16277
BibTeX
@article{Zhang2023,
author = {Zhang, Xueren and Jiang, Yangkang and Luo, Chen and Li, Dengwang and Niu, Tianye and Yu, Gang},
title = {Image‐based scatter correction for cone‐beam CT using flip swin transformer U‐shape network},
journal = {Medical Physics},
year = {2023},
volume = {50},
number = {8},
pages = {5002--5019},
doi = {10.1002/mp.16277}
}
EUVIMED