EUVIMEDOpdag EUVIMED
Crossref

Development of a compact linear accelerator to generate ultrahigh dose rate high‐energy X‐rays for FLASH radiotherapy applications

Focheng Liu, Jiaru Shi, Hao Zha, Guohua Li, An Li, Weihang Gu, Ankang Hu, Qiang Gao, Haokun Wang, Liang Zhang, Jinsheng Liu, Yaohong Liu and 3 more

Medical Physics · 2023

DOI: 10.1002/mp.16199 ↗

At a glance

Journal article in Medical Physics, 2023. Written by Focheng Liu and 14 co-authors. Institution: Department of Engineering Physics, Tsinghua University, Beijing, China. Major MEDLINE topics: Photons, Particle Accelerators. Cited 30 times so far (Crossref); 33 references. Funded by: Ministry of Science and Technology of the People's Republic of China, National key research and development program number.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

In recent years, the FLASH effect, in which ultrahigh dose rate (UHDR) radiotherapy (RT) can significantly reduce toxicity to normal tissue while maintaining antitumor efficacy, has been verified in many studies and even applied in human clinical cases. This work evaluates whether a room‐temperature radio‐frequency (RF) linear accelerator (linac) system can produce UHDR high‐energy X‐rays exceeding a dose rate of 40 Gy/s at a clinical source‐surface distance (SSD), exploring the possibility of a compact and economical clinical FLASH RT machine suitable for most hospital treatmentrooms.

Methods

A 1.65 m long S‐band backward‐traveling‐wave (BTW) electron linac was developed to generate high‐current electron beams, supplied by a commercial klystron‐based power source. A tungsten‐copper electron‐to‐photon conversion target for UHDR X‐rays was designed and optimized with Monte Carlo (MC) simulations using Geant4 and thermal finite element analysis (FEA) simulations using ANSYS. EBT3 and EBT‐XD radiochromic films, which were calibrated with a clinical machine Varian VitalBeam, were used for absolute dose measurements. A PTW ionization chamber detector was used to measure the relative total dose and a plane‐parallel ionization chamber detector was used to measure the relative normalized dose of each pulse.

Results

The BTW linac generated 300‐mA‐pulse‐current 11 MeV electron beams with 29 kW mean beam power, and the conversion target could sustain this high beam power within a maximum irradiation duration of 0.75 s. The mean energy of the produced X‐rays was 1.66 MeV in the MC simulation. The measured flat‐filter‐free (FFF) maximum mean dose rate of the room‐temperature linac exceeded 80 Gy/s at an SSD of 50 cm and 45 Gy/s at an SSD of 67.9 cm, both at a 2.1 cm depth of the water phantom. The FFF radiation fields at 50 cm and 67.9 cm SSD at a 2.1 cm depth of the water phantom showed Gaussian‐like distributions with 14.3 and 20 cm full‐width at half‐maximum (FWHM) values, respectively.

Conclusion

This work demonstrated the feasibility of UHDR X‐rays produced by a room‐temperature RF linac, and explored the further optimization of system stability. It shows that a simple and compact UHDR X‐ray solution can be facilitated for both FLASH‐RT scientific research and clinical applications.

Subjects

MeSH terms (MEDLINE)

PhotonsParticle AcceleratorsHumansX-RaysRadiographyWaterRadiometryRadiotherapy DosageMonte Carlo Method

Author keywords

FLASH radiotherapyhigh-energy X-raysroom-temperature linear acceleratorultrahigh dose rate radiotherapy

Substances

Water

Authors and institutions

  • Department of Engineering Physics, Tsinghua University, Beijing, China.
  • Key Laboratory of Particle and Radiation Imaging of Ministry of Education, Tsinghua University, Beijing, China.
  • Department of Linac, Nuctech Company Limited, Beijing, China.
  • Fifth Medical Center of Chinese PLA General of Hospital, Beijing, China.

Funding

  • Ministry of Science and Technology of the People's Republic of China
  • National key research and development program number

Cite

APA

Liu, F., Shi, J., Zha, H., Li, G., Li, A., Gu, W., Hu, A., Gao, Q., Wang, H., Zhang, L., Liu, J., Liu, Y., Xu, H., Tang, C., & Chen, H. (2023). Development of a compact linear accelerator to generate ultrahigh dose rate high‐energy X‐rays for FLASH radiotherapy applications. Medical Physics. https://doi.org/10.1002/mp.16199

Vancouver

Liu F, Shi J, Zha H, Li G, Li A, Gu W, et al. Development of a compact linear accelerator to generate ultrahigh dose rate high‐energy X‐rays for FLASH radiotherapy applications. Medical Physics. 2023. doi:10.1002/mp.16199

BibTeX
@article{Liu2023,
  author = {Liu, Focheng and Shi, Jiaru and Zha, Hao and Li, Guohua and Li, An and Gu, Weihang and Hu, Ankang and Gao, Qiang and Wang, Haokun and Zhang, Liang and Liu, Jinsheng and Liu, Yaohong and Xu, Huijun and Tang, Chuanxiang and Chen, Huaibi},
  title = {Development of a compact linear accelerator to generate ultrahigh dose rate high‐energy X‐rays for FLASH radiotherapy applications},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16199}
}
Start for free →