EUVIMEDEUVIMED entdecken
Multizentrische StudieVergleichsstudie

Effect of the patient‐specific instrumentation guidance on the accurate positioning of the baseplate and screws in reverse total shoulder arthroplasty: Multicenter comparative study

Jong Pil Yoon iD, Myung Sun Kim iD, Hyun Tae Kim iD, Dong Hwan Lee iD, Sung Wook Hong iD, Jong Ho Kim iD, Seok Won Chung iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12781 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Jong Pil Yoon und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Kyungpook National University College of Medicine, Daegu, Korea. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Bone Screws, Surgery, Computer-Assisted, Shoulder Joint. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Konkuk University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the accuracy of implant placement using patient‐specific instrumentation (PSI) in reverse total shoulder arthroplasty (RTSA) compared to conventional techniques, and to determine whether PSI enhances the precision of glenoid component and screw positioning.

Methods

This retrospective, multi‐centre comparative study included 135 patients who underwent primary RTSA across four tertiary medical centres. Patients were divided into two groups: 65 received RTSA with PSI, and 70 underwent conventional RTSA. PSI employed 3D‐printed guides, based on preoperative CT scans, to precisely guide the placement of the glenoid component and peripheral screws. Postoperative imaging was used to assess screw trajectory and length, as well as baseplate version, inclination, and entry point trajectory.

Results

PSI demonstrated significantly greater accuracy in baseplate positioning compared to conventional methods, with improved outcomes in version (mean deviation: 1.5 ± 1.1° vs. 6.7 ± 5.4°, p < 0.001), inclination (2.8 ± 1.5° vs. 5.3 ± 3.7°, p = 0.012), and entry point location (1.9 ± 1.2 mm vs. 3.2 ± 1.5 mm, p = 0.037). Although mean postoperative screw lengths were greater in all directions in the PSI group, the differences were not statistically significant (all p > 0.05). Similarly, deviations from planned screw lengths were lower in the PSI group but did not reach statistical significance (all p > 0.05). Notably, PSI significantly improved the precision of peripheral screw trajectories, particularly in the superior and inferior screws across superior–inferior (S/I: p = 0.037 and p = 0.012) and anterior–posterior directions (A/P: p = 0.043 and p = 0.015), as well as in anterior ( p = 0.004) and posterior screws ( p = 0.008) in the A/P direction. The PSI group also had significantly fewer cases of screw prominence (9 vs. 23), and no cases of screw insertion failure or notch involvement were observed. No major complications occurred in either group.

Conclusion

PSI significantly improves the accuracy of implant placement in RTSA compared to conventional techniques, potentially reducing postoperative complications. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderBone ScrewsSurgery, Computer-AssistedShoulder JointHumansRetrospective StudiesFemaleMaleAgedMiddle AgedTomography, X-Ray ComputedAged, 80 and overPrinting, Three-Dimensional

Stichwörter der Autor:innen

complicationsimplant precisionpatient‐specific instrumentation (PSI)reverse total shoulder arthroplasty (RTSA)surgical outcomes

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Kyungpook National University College of Medicine, Daegu, Korea.
  • Department of Orthopaedic Surgery, Chonnam National University Hospital, Gwangju, Korea.
  • Department of Orthopaedic Surgery, Konkuk University School of Medicine, Seoul, Korea.
  • Department of Orthopaedic Surgery, Yeouido St. Mary's Hospital, the Catholic University, Seoul, Korea.

ORCID-Profile: Jong Pil Yoon, Myung Sun Kim, Hyun Tae Kim, Dong Hwan Lee, Sung Wook Hong, Jong Ho Kim, Seok Won Chung

Förderung

  • Konkuk University

Zitieren

APA

Yoon, J. P., Kim, M. S., Kim, H. T., Lee, D. H., Hong, S. W., Kim, J. H., & Chung, S. W. (2025). Effect of the patient‐specific instrumentation guidance on the accurate positioning of the baseplate and screws in reverse total shoulder arthroplasty: Multicenter comparative study. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12781

Vancouver

Yoon JP, Kim MS, Kim HT, Lee DH, Hong SW, Kim JH, et al. Effect of the patient‐specific instrumentation guidance on the accurate positioning of the baseplate and screws in reverse total shoulder arthroplasty: Multicenter comparative study. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12781

BibTeX
@article{Yoon2025,
  author = {Yoon, Jong Pil and Kim, Myung Sun and Kim, Hyun Tae and Lee, Dong Hwan and Hong, Sung Wook and Kim, Jong Ho and Chung, Seok Won},
  title = {Effect of the patient‐specific instrumentation guidance on the accurate positioning of the baseplate and screws in reverse total shoulder arthroplasty: Multicenter comparative study},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12781}
}
Kostenlos starten →