Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2026. Verfasst von Maximilian Uhler und 6 weiteren Autor:innen. Beteiligte Einrichtung: Research Center of Biomechanics and Implant Technology, Clinic for Orthopedics and Trauma Surgery, University Hospital Heidelberg, Heidelberg, German…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Shoulder Fractures, Fracture Fixation, Internal. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Open Access funding enabled and organized by Projekt DEAL..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sufficient refixation and healing is crucial for the function of a reverse shoulder arthroplasty within the treatment of proximal humeral fractures. Conventional refixation with suture cerclage is time‐consuming and leads to healing in only 60–70% of cases. This study used a biomechanical test to investigate two different refixation procedures for treating 4‐fragment fractures of the proximal humerus. Eight paired humerus specimens were randomly assigned to two groups and treated with reverse shoulder prostheses. One group received conventional suture cerclage fixation for 4‐fragment fractures, while the other used a novel TendoClip system with screw fixation. Both groups were subjected to increasing cyclic tensile forces until failure. Fragment movement relative to the prosthesis stem was measured to assess primary stability. Tensile forces generated in the first four load levels resulted in significantly different relative motions between the TendoClip and cerclage groups. 3 out of 8 specimens in the TendoClip group could be loaded over all load levels. This was not possible for any cerclage group specimens. Recorded failure mechanisms showed that fixed bone fragments of the cerclage procedure were affected significantly more often by loosening and visible relative movements compared to the TendoClip procedure. However, limitations of the TendoClip restoration were also observed. In 2 of 8 cases, a bone fragment was torn out of the fixation, and two other implants showed a loss of fixation in relation to the humerus. This study reveals that the TendoClip procedure could be an alternative to conventional cerclage fixation procedures in multifragmentary proximal humerus fractures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderShoulder FracturesFracture Fixation, InternalHumansAgedBiomechanical PhenomenaMaleFemaleAged, 80 and overBone ScrewsMiddle AgedTensile Strength

Stichwörter der Autor:innen

in vitro investigationproximal humeral fracturereverse shoulder arthroplastytuberosity reattachment

Autor:innen und Institutionen

  • Research Center of Biomechanics and Implant Technology, Clinic for Orthopedics and Trauma Surgery, University Hospital Heidelberg, Heidelberg, Germany.
  • Department for Shoulder-Elbow Surgery and Sports Orthopedics, Schoen Clinic Duesseldorf, Duesseldorf, Germany.
  • Department for Traumatology and Orthopedics, Hospital Marienhaus St. Wendel-Ottweiler, St. Wendel, Germany.
  • Heinrich-Heine-University of Duesseldorf, Duesseldorf, Germany.
  • Department of Orthopaedics, University Hospital Heidelberg, Heidelberg, Germany.

Förderung

  • Open Access funding enabled and organized by Projekt DEAL.

Zitieren

APA

Uhler, M., Patzer, T., Fleischer, J., Knopp, D., Knappe, K., Bülhoff, M., & Kretzer, J. P. (2026). Primary Stability of a New TendoClip Fixation for Tuberosity Refixation in Total Shoulder Arthroplasty. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.70105

Vancouver

Uhler M, Patzer T, Fleischer J, Knopp D, Knappe K, Bülhoff M, et al. Primary Stability of a New TendoClip Fixation for Tuberosity Refixation in Total Shoulder Arthroplasty. Journal of Orthopaedic Research. 2026. doi:10.1002/jor.70105

BibTeX
@article{Uhler2026,
  author = {Uhler, Maximilian and Patzer, Thilo and Fleischer, Jörg and Knopp, Daniel and Knappe, Kevin and Bülhoff, Matthias and Kretzer, Jan Philippe},
  title = {Primary Stability of a New TendoClip Fixation for Tuberosity Refixation in Total Shoulder Arthroplasty},
  journal = {Journal of Orthopaedic Research},
  year = {2026},
  doi = {10.1002/jor.70105}
}
Kostenlos starten →