EUVIMEDEUVIMED entdecken
Multizentrische StudieRandomisierte kontrollierte StudieVergleichsstudie

Patient-specific instrumentation vs. a free-hand technique for glenoid baseplate and peripheral screw placement in reverse total shoulder arthroplasty using the Exactech implant system: a multicenter randomized controlled trial

Hyojune Kim, HwaYong Lee, Tae Kang Lim, Seong Hun Kim, Hyo-Jin Lee, Hyeon Jang Jeong, Min Soo Shon, In-Ho Jeon, Kyoung Hwan Koh

Journal of Shoulder and Elbow Surgery · 2025

DOI: 10.1016/j.jse.2025.11.014 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025. Verfasst von Hyojune Kim und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Hospital of Chung-Ang University of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Bone Screws, Shoulder Joint, Shoulder Prosthesis. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Korea Health Industry Development Institute, Ministry of Health and Welfare.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Accurate positioning of the glenoid baseplate and peripheral screws is critical in reverse total shoulder arthroplasty (rTSA). Patient-specific instrumentation (PSI) has been introduced to improve surgical accuracy, but its benefits over conventional free-hand techniques remain uncertain. This study aimed to evaluate the accuracy of glenoid baseplate and peripheral screw placement between PSI-assisted and conventional free-hand rTSA. METHODS: We conducted a prospective, multicenter, parallel-group, single-blinded, superiority randomized controlled trial across 7 tertiary centers between March 2022 and December 2024. Patients aged ≥65 years undergoing primary rTSA were randomized 1:1 to PSI or free-hand group through a centralized web-based electronic case report form. No cross-over occurred and all analyses were performed on an intention-to-treat basis. A standardized implant system (Exactech, Gainesville, FL, USA) was used in all cases. The primary outcome was the proportion of patients with postoperative computed tomography-based deviation error from preoperative planning, including version (≥5°), inclination (≥5°), or position offset (≥2.5 mm) errors. The secondary outcomes included continuous deviation values and accuracy of peripheral screw placement (anteroposterior [AP] gap, superoinferior (SI) gap, and length gap deviations). Effect sizes with 95% confidence intervals (CIs) were reported. RESULTS: Of 106 patients, 53 were included in the PSI and free-hand groups each. Baseline demographics and clinical characteristics were comparable between the groups. Baseplate positioning was similar between the groups, with version error 5 ± 5° vs. 5 ± 5°, inclination error 6 ± 5° vs. 5 ± 4° (mean difference +0.9°, 95% CI -0.8 to +2.6; P = .309), and positional offset 3 ± 2 mm vs. 4 ± 2 mm (mean difference -0.3 mm, 95% CI -1.1 to +0.5; P = .496). Conversely, PSI significantly improved peripheral screw placement accuracy, including AP gap (-1 ± 3° vs. 1 ± 6°; mean difference -1.9°, 95% CI -3.7 to -0.1; P = .041), SI gap (-2 ± 4° vs. 1 ± 6°; mean difference -2.7°, 95% CI -4.7 to -0.8; P = .008), superior length gap (1 ± 6 mm vs. -2 ± 8 mm; mean difference +3.0 mm, 95% CI 0.2 to 5.8; P = .039), and inferior AP gap (1 ± 6° vs. -3 ± 6°; mean difference +4.2°, 95% CI 2.0 to 6.4; P 5°) were significantly less frequent in the PSI group for anterior (11.3% vs. 43.4%; P < .001) and superior (20.8% vs. 41.5%; P = .035) SI gap. CONCLUSION: In primary rTSA, PSI did not improve glenoid baseplate positioning compared to the free-hand technique but significantly enhanced the accuracy of peripheral screw placement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderBone ScrewsShoulder JointShoulder ProsthesisSurgery, Computer-AssistedHumansMaleFemaleAgedSingle-Blind MethodProspective StudiesAged, 80 and overTreatment Outcome

Stichwörter der Autor:innen

3D printingPatient-specific instrumentationfree-handperipheral screw guidespreoperative planningreverse total shoulder arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Hospital of Chung-Ang University of Medicine, Seoul, Republic of Korea.
  • Anymedi Inc, Seoul, Republic of Korea.
  • Department of Orthopedic Surgery, Nowon Eulji Medical Center, Eulji University School of Medicine, Seoul, Republic of Korea.
  • Department of Orthopedic Surgery, National Health Insurance Service Ilsan Hospital, Gyeonggi, Republic of Korea.
  • Department of Orthopedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.

Förderung

  • Korea Health Industry Development Institute
  • Ministry of Health and Welfare

Zitieren

APA

Kim, H., Lee, H., Lim, T. K., Kim, S. H., Lee, H. J., Jeong, H. J., Shon, M. S., Jeon, I. H., & Koh, K. H. (2025). Patient-specific instrumentation vs. a free-hand technique for glenoid baseplate and peripheral screw placement in reverse total shoulder arthroplasty using the Exactech implant system: a multicenter randomized controlled trial. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2025.11.014

Vancouver

Kim H, Lee H, Lim TK, Kim SH, Lee HJ, Jeong HJ, et al. Patient-specific instrumentation vs. a free-hand technique for glenoid baseplate and peripheral screw placement in reverse total shoulder arthroplasty using the Exactech implant system: a multicenter randomized controlled trial. Journal of Shoulder and Elbow Surgery. 2025. doi:10.1016/j.jse.2025.11.014

BibTeX
@article{Kim2025,
  author = {Kim, Hyojune and Lee, HwaYong and Lim, Tae Kang and Kim, Seong Hun and Lee, Hyo-Jin and Jeong, Hyeon Jang and Shon, Min Soo and Jeon, In-Ho and Koh, Kyoung Hwan},
  title = {Patient-specific instrumentation vs. a free-hand technique for glenoid baseplate and peripheral screw placement in reverse total shoulder arthroplasty using the Exactech implant system: a multicenter randomized controlled trial},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2025},
  doi = {10.1016/j.jse.2025.11.014}
}
Kostenlos starten →