EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

The impact of a prophylactic skin dressing on surface‐guided patient positioning in chest wall Radiation Therapy

James Cumming iD, Kenton Thompson, Katrina Woodford, Vanessa Panettieri iD, Daniel Sapkaroski iD

Journal of Medical Radiation Sciences · 2024

DOI: 10.1002/jmrs.781 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Medical Radiation Sciences, 2024. Verfasst von James Cumming und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Therapy Services, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Patient Positioning, Radiotherapy, Image-Guided, Occlusive Dressings, Silicones. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Surface‐guided radiation therapy (SGRT) has emerged as a powerful tool to improve patient setup accuracy in radiation therapy (RT). Combined with the goal of increasing RT accuracy is an ongoing effort to decrease RT side effects. The application of a prophylactic skin dressing to the treatment site is a well‐documented method of reducing skin‐related side effects from RT. This paper aims to investigate whether the application of Mepitel, a prophylactic skin dressing, has an impact on the accuracy of surface‐guided patient setups in chest wall RT.

Methods

A retrospective analysis of daily image‐guided Online Corrections (OLCs) from patients undergoing chest wall irradiation with SGRT was performed. Translational (superior–inferior, lateral, and anterior–posterior) OLC magnitude and direction were compared between patients treated with Mepitel applied and those treated without. Systematic and random errors were calculated and compared between groups.

Results

OLCs from 275 fractions were analysed. Mean OLCs were larger for patients with Mepitel applied in the superior_inferior axis (0.34 vs. 0.22 cm, P = 0.049) and for the combined translational vector (0.54 vs. 0.43 cm, P = 0.043). Combined translational systematic error was slightly larger for patients with Mepitel applied (0.15 vs. 0.09 cm).

Conclusion

Mepitel can impact the accuracy of SGRT patient‐positioning in chest wall RT. The variation however is small and unlikely to have any clinical impact if SGRT is coupled with image guidance and appropriate PTV margins. Further investigation is required to assess the effect of Mepitel on SGRT accuracy in other treatment sites, as well as any potential dosimetric impacts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Patient PositioningRadiotherapy, Image-GuidedOcclusive DressingsSiliconesThoracic WallBreast NeoplasmsBreast Neoplasms, MaleRetrospective StudiesRadiodermatitisRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedSkinRadiotherapy, AdjuvantMastectomyHumansFemaleMaleAdultMiddle AgedAgedAged, 80 and overRadiometry

Stichwörter der Autor:innen

BreastMepitelchest wallradiation therapyradiotherapyskin dressingsurface guided radiation therapy

Substanzen

mepitelSilicones

Autor:innen und Institutionen

  • Department of Radiation Therapy Services, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
  • Department of Medical Imaging and Radiation Sciences, Monash University, Clayton, Victoria, Australia.
  • Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
  • Central Clinical School, Monash University, Melbourne, Victoria, Australia.
  • Department of Health and Biomedical Sciences, Royal Melbourne Institute of Technology, Bundoora, Victoria, Australia.
  • The Sir Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne, Victoria, Australia.

ORCID-Profile: James Cumming, Vanessa Panettieri, Daniel Sapkaroski

Zitieren

APA

Cumming, J., Thompson, K., Woodford, K., Panettieri, V., & Sapkaroski, D. (2024). The impact of a prophylactic skin dressing on surface‐guided patient positioning in chest wall Radiation Therapy. Journal of Medical Radiation Sciences. https://doi.org/10.1002/jmrs.781

Vancouver

Cumming J, Thompson K, Woodford K, Panettieri V, Sapkaroski D. The impact of a prophylactic skin dressing on surface‐guided patient positioning in chest wall Radiation Therapy. Journal of Medical Radiation Sciences. 2024. doi:10.1002/jmrs.781

BibTeX
@article{Cumming2024,
  author = {Cumming, James and Thompson, Kenton and Woodford, Katrina and Panettieri, Vanessa and Sapkaroski, Daniel},
  title = {The impact of a prophylactic skin dressing on surface‐guided patient positioning in chest wall Radiation Therapy},
  journal = {Journal of Medical Radiation Sciences},
  year = {2024},
  doi = {10.1002/jmrs.781}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche