Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Hui Zhao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Oncology Department, University of Utah, Salt Lake City, Utah, USA. Hauptthemen laut MEDLINE: Radiotherapy, Image-Guided, Thoracic Wall. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Surface‐guided radiation therapy (SGRT) systems have been widely installed and utilized on linear accelerators. However, the use of SGRT with proton therapy is still a newly developing field, and published reports are currently very limited.
Purpose
To assess the clinical application and alignment agreement of SGRT with CT‐on‐rails (CTOR) and kV‐2D image‐guided radiation therapy (IGRT) for breast treatment using proton therapy.
Methods
Four patients receiving breast or chest wall treatment with proton therapy were the subjects of this study. Patient #1′s IGRT modalities were a combination of kV‐2D and CTOR. CTOR was the only imaging modality for patients #2 and #3, and kV‐2D was the only imaging modality for patient #4. The patients’ respiratory motions were assessed using a 2‐min surface position recorded by the SGRT system during treatment. SGRT offsets reported after IGRT shifts were recorded for each fraction of treatment. The agreement between SGRT and either kV‐2D or CTOR was evaluated.
Results
The respiratory motion amplitude was
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Radiation Oncology Department, University of Utah, Salt Lake City, Utah, USA.
- University of Texas Southwestern, Dallas, Texas, USA.
ORCID-Profile: Vikren Sarkar, Adam Paxton, Ryan G Price
Zitieren
APA
Zhao, H., Sarkar, V., St James, S., Paxton, A., Su, F. F., Price, R. G., Dial, C., Poppe, M., Gaffney, D., & Salter, B. (2024). Verification of surface‐guided radiation therapy (SGRT) alignment for proton breast and chest wall patients by comparison to CT‐on‐rails and kV‐2D alignment. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14263
Vancouver
Zhao H, Sarkar V, St James S, Paxton A, Su FF, Price RG, et al. Verification of surface‐guided radiation therapy (SGRT) alignment for proton breast and chest wall patients by comparison to CT‐on‐rails and kV‐2D alignment. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14263
BibTeX
@article{Zhao2024,
author = {Zhao, Hui and Sarkar, Vikren and St James, Sara and Paxton, Adam and Su, Fan-Chi Frances and Price, Ryan G and Dial, Christian and Poppe, Matthew and Gaffney, David and Salter, Bill},
title = {Verification of surface‐guided radiation therapy (SGRT) alignment for proton breast and chest wall patients by comparison to CT‐on‐rails and kV‐2D alignment},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
doi = {10.1002/acm2.14263}
}
EUVIMED