EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Concordance Between MR Safety Guidance Documents on Conditions for a Safe MR Environment

Ives R Levesque iD, Véronique Fortier iD, Jorge Campos Pazmiño, Evan McNabb iD

Journal of Magnetic Resonance Imaging · 2026

DOI: 10.1002/jmri.70444 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Ives R Levesque und 3 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Unit, McGill University, Montréal, Québec, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fond de recherche du Québec - Santé, Fondation de l'Hôpital Général de Montréal, Institut de recherche du Centre universitaire de santé McGill.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Environmental conditions established at facility design, construction, updates, and/or procurement of specialized equipment are the foundation of safe MR practice. Establishing an institutional MR safety program must take into consideration the conditions of the MR environment, and staff training should be tailored to its features. Purpose/Hypothesis To identify the concordance on conditions for a safe MR environment among a variety of widely known national guidance documents. Study Type Analysis of guidance documents. Population/Subjects/Phantom/Specimen/Animal Model Not applicable. Field Strength/Sequence Not specific to field strength. Assessment Information was extracted from national MR safety guidance documents about the expected conditions in a safe MR environment, and categorized among (1) facility design, (2) MR equipment selection, and (3) peripheral equipment. Commonalities and differences were identified. Statistical Tests Descriptive statistics.

Results

Six publicly available national guidance documents for MR safety were obtained, from countries with relatively high density of MR systems (between 9 and 38 MR systems per million inhabitants): Australia, New Zealand, Sweden, Switzerland, UK, and USA. Full or partial concordance was observed among many measures related to facility design (21/25 conditions), MR equipment features (7/9 conditions), and peripheral equipment (10/13 conditions). Data Conclusion This work identified the common and divergent recommendations on facilities and equipment from a variety of guidance documents from national sources. Highlighting common (and uncommon) features recommended by guidance can help users identify weaknesses in their MR environment. This could inform jurisdictions/countries without official guidance and serve in the development of future guidance documents or MR safety training materials. Evidence Level 5. Technical Efficacy 1.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingHumansEquipment SafetyPatient SafetyAnimalsPhantoms, Imaging

Stichwörter der Autor:innen

MR environmentMR safetyMR safety guidancefacility designhazard controls

Autor:innen und Institutionen

  • Medical Physics Unit, McGill University, Montréal, Québec, Canada.
  • Research Institute of the McGill University Centre, Montréal, Québec, Canada.
  • Medical Imaging, McGill University Health Centre, Montréal, Québec, Canada.
  • Department of Medical Physics, McGill University Health Centre, Montréal, Québec, Canada.

ORCID-Profile: Ives R Levesque, Véronique Fortier, Evan McNabb

Förderung

  • Fond de recherche du Québec - Santé
  • Fondation de l'Hôpital Général de Montréal
  • Institut de recherche du Centre universitaire de santé McGill
  • Institut de recherche, Centre universitaire de santé McGill

Zitieren

APA

Levesque, I. R., Fortier, V., Campos Pazmiño, J., & McNabb, E. (2026). Concordance Between MR Safety Guidance Documents on Conditions for a Safe MR Environment. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70444

Vancouver

Levesque IR, Fortier V, Campos Pazmiño J, McNabb E. Concordance Between MR Safety Guidance Documents on Conditions for a Safe MR Environment. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70444

BibTeX
@article{Levesque2026,
  author = {Levesque, Ives R and Fortier, Véronique and Campos Pazmiño, Jorge and McNabb, Evan},
  title = {Concordance Between MR Safety Guidance Documents on Conditions for a Safe MR Environment},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1002/jmri.70444}
}
Kostenlos starten →