Phantom Safety Assessment of 3 Tesla Magnetic Resonance Imaging in Directional and Sensing Deep Brain Stimulation Devices

Riccardo Ludovichetti, Clement T Chow, Sriranga Kashyap, Ian Connell, Benson Yang, Simon J Graham, Gavin Elias, Brendan Santyr, Asma Naheed, Diego Martinez, Michael Colditz, Jürgen Germann und 4 weitere

Stereotactic and Functional Neurosurgery · 2024

DOI: 10.1159/000542725 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stereotactic and Functional Neurosurgery, 2024. Verfasst von Riccardo Ludovichetti und 15 weiteren Autor:innen. Beteiligte Einrichtung: Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada, riccardoludo@gmail.com. Hauptthemen laut MEDLINE: Deep Brain Stimulation, Phantoms, Imaging, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Magnetic resonance imaging (MRI) is both a crucial clinical and research tool for patients with deep brain stimulation (DBS) devices. However, safety concerns predominantly related to device heating have limited such imaging. Rigorous safety testing has demonstrated that scanning outside of vendor guidelines may be both safe and feasible, unlocking unique opportunities for advanced imaging in this patient population. Currently, however, 3T MRI safety data including advanced MRI sequences in novel directional and sensing DBS devices is lacking.

Methods

An anthropomorphic phantom replicating bilateral DBS system was used to assess the temperature rise at the electrode tips, implantable pulse generator, and cranial loop during acquisition of routine clinical sequences (three dimensional [3D] T1, GRE T2*, T2 FSE) and advanced imaging sequences including functional MRI (fMRI), arterial spin labelling (ASL), and diffusion weighted imaging (DWI). Measures of radiofrequency exposure (specific absorption rate [SAR] and root-mean square value of the MRI effective component of the radiofrequency transmission field [B1+rms]) were also recorded as an indirect measure of heating. Testing involved both a new directional and sensing DBS device (Medtronic: B30015 leads and Percept PC neurostimulator) and a previous-generation DBS device (Medtronic: 3,387 leads and Percept PC neurostimulator) in combination with a state-of-the-art (Siemens MAGNETOM Prisma) and a previous-generation (GE Signa HDxt) 3T MRI scanner.

Results

On the state-of-the-art 3T MRI scanner, the new DBS device produced safe temperature rises with clinically used sequences and fMRI but not with other advanced sequences such as DWI and ASL, which also exceeded B1+rms vendor guidelines (i.e., ≤2 μT). When scanned on the previous MRI scanner, the recent DBS device produced overall lower and slower temperature rises compared to the previous DBS model. Among the sequences performed on this scanner, several (3D T1, DWI, T2 FSE, and ASL) exceeded the approved SAR vendor limit (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep Brain StimulationPhantoms, ImagingMagnetic Resonance ImagingHumansElectrodes, ImplantedEquipment SafetyBrain

Stichwörter der Autor:innen

Deep brain stimulationFunctional MRIFunctional imagingMagnetic resonance imagingSafety testing

Autor:innen und Institutionen

  • Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada, riccardoludo@gmail.com.
  • Division of Neurosurgery, Department of Surgery, University Health Network, Toronto, Ontario, Canada.
  • Krembil Research Institute, University Health Network, Toronto, Ontario, Canada.
  • Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Melbourne, Victoria, Australia.
  • Department of Medical Biophysics, Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.
  • Medical Engineering, University Health Network, Toronto, Ontario, Canada.

Zitieren

APA

Ludovichetti, R., Chow, C. T., Kashyap, S., Connell, I., Yang, B., Graham, S. J., Elias, G., Santyr, B., Naheed, A., Martinez, D., Colditz, M., Germann, J., Vetkas, A., Uludağ, K., Lozano, A. M., & Boutet, A. (2024). Phantom Safety Assessment of 3 Tesla Magnetic Resonance Imaging in Directional and Sensing Deep Brain Stimulation Devices. Stereotactic and Functional Neurosurgery. https://doi.org/10.1159/000542725

Vancouver

Ludovichetti R, Chow CT, Kashyap S, Connell I, Yang B, Graham SJ, et al. Phantom Safety Assessment of 3 Tesla Magnetic Resonance Imaging in Directional and Sensing Deep Brain Stimulation Devices. Stereotactic and Functional Neurosurgery. 2024. doi:10.1159/000542725

BibTeX
@article{Ludovichetti2024,
  author = {Ludovichetti, Riccardo and Chow, Clement T and Kashyap, Sriranga and Connell, Ian and Yang, Benson and Graham, Simon J and Elias, Gavin and Santyr, Brendan and Naheed, Asma and Martinez, Diego and Colditz, Michael and Germann, Jürgen and Vetkas, Artur and Uludağ, Kâmil and Lozano, Andres M and Boutet, Alexandre},
  title = {Phantom Safety Assessment of 3 Tesla Magnetic Resonance Imaging in Directional and Sensing Deep Brain Stimulation Devices},
  journal = {Stereotactic and Functional Neurosurgery},
  year = {2024},
  doi = {10.1159/000542725}
}
Kostenlos starten →