EUVIMEDEUVIMED entdecken
Vergleichsstudie

Diagonal DWI : A Time‐Efficient Alternative to 3‐Scan Trace DWI for Breast Lesion Evaluation at 3.0‐T MRI —A Phantom Study and Clinical Assessment

Yusuke Jo, Yuki Sato, Mami Iima iD, Hiroko Satake iD, Yunhao Zhang, Yutaka Kato, Satoko Ishigaki, Ryota Hyodo iD, Aki Mano, Yoshito Ichiba, Shinji Naganawa iD

Journal of Magnetic Resonance Imaging · 2026

DOI: 10.1002/jmri.70155 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Yusuke Jo und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Breast Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: JSPS KAKENHI, Japan Agency for Medical Research and Development.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Diffusion‐weighted imaging (DWI) in breast MRI requires balancing image quality with acquisition time. Reducing scan time without sacrificing diagnostic performance could improve patient comfort and workflow.

Purpose

To compare 3‐scan trace DWI (tDWI) and diagonal DWI (dDWI) for breast lesion evaluation using both phantom and clinical assessments, focusing on image quality metrics and diagnostic performance. Study Type Retrospective comparative study. Population A commercially available breast diffusion phantom (Caliber MRI; Boulder, CO, USA) and 92 consecutive participants were initially enrolled. After excluding 23 due to having no confirmed lesion, and 15 with non‐mass lesions, 54 patients (median age 55.5 years, range 21–82) were analyzed. Field Strength/Sequence 3‐T, tDWI (120 s) and dDWI (74 s) with identical parameters except for diffusion gradient directions, with dDWI reducing scan time by 38%. Assessment Phantom studies measured apparent diffusion coefficient (ADC) and estimated signal‐to‐noise ratio (eSNR). Clinical studies evaluated ADC, contrast‐to‐noise ratio (CNR), and contrast ratio (CR) from ROIs in lesions, normal breast tissue, and fat. Three radiologists scored lesion conspicuity and image quality. Statistical Tests Due to non‐normal data distribution, the Wilcoxon signed‐rank test compared metrics between sequences. The ADC coefficient of variation (CV) was calculated. A p ‐value < 0.05 was considered significant. Results dDWI significantly improved image quality by reducing artifacts, especially those originating from the nipple and in the breast tissue periphery, and slightly better lesion conspicuity. No significant difference was found for eSNR in breast phantom studies ( p = 0.31 for b = 0; and p = 0.84 for b = 800 s/mm 2 ). tDWI demonstrated significantly higher CNR for breast tissue and fat. tDWI also showed lower CR values for tumor/breast tissue and lower values for tumor/fat. ADC measurements were similar between techniques (CV = 4.20%). Data Conclusion dDWI provides a 38% shorter acquisition time than tDWI while maintaining comparable quantitative performance. dDWI demonstrates improved image quality, particularly in challenging anatomical regions, though tDWI yields higher contrast‐to‐noise ratio values. Evidence Level 3. Technical Efficacy Stage 2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingBreast NeoplasmsHumansFemalePhantoms, ImagingMiddle AgedAdultAgedRetrospective StudiesBreastAged, 80 and overSignal-To-Noise RatioYoung AdultReproducibility of ResultsImage Processing, Computer-AssistedImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

acquisition timeapparent diffusion coefficientbreast MRIdiffusion‐weighted imagingimage quality

Autor:innen und Institutionen

  • Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
  • Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
  • Department of Radiological Technology, Nagoya University Hospital, Nagoya, Aichi, Japan.
  • Siemens Healthcare K.K., Shinagawa-ku, Tokyo, Japan.

ORCID-Profile: Mami Iima, Hiroko Satake, Ryota Hyodo, Shinji Naganawa

Förderung

  • JSPS KAKENHI
  • Japan Agency for Medical Research and Development

Zitieren

APA

Jo, Y., Sato, Y., Iima, M., Satake, H., Zhang, Y., Kato, Y., Ishigaki, S., Hyodo, R., Mano, A., Ichiba, Y., & Naganawa, S. (2026). Diagonal DWI : A Time‐Efficient Alternative to 3‐Scan Trace DWI for Breast Lesion Evaluation at 3.0‐T MRI —A Phantom Study and Clinical Assessment. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70155

Vancouver

Jo Y, Sato Y, Iima M, Satake H, Zhang Y, Kato Y, et al. Diagonal DWI : A Time‐Efficient Alternative to 3‐Scan Trace DWI for Breast Lesion Evaluation at 3.0‐T MRI —A Phantom Study and Clinical Assessment. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70155

BibTeX
@article{Jo2026,
  author = {Jo, Yusuke and Sato, Yuki and Iima, Mami and Satake, Hiroko and Zhang, Yunhao and Kato, Yutaka and Ishigaki, Satoko and Hyodo, Ryota and Mano, Aki and Ichiba, Yoshito and Naganawa, Shinji},
  title = {Diagonal DWI : A Time‐Efficient Alternative to 3‐Scan Trace DWI for Breast Lesion Evaluation at 3.0‐T MRI —A Phantom Study and Clinical Assessment},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1002/jmri.70155}
}
Kostenlos starten →