Bilateral Breast Gradient Insert Prototype for Strong Diffusion Encoding at 3 T
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 414-424
DOI: 10.1002/mrm.70612 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 17.10.2026. Verfasst von Gerrit Cornelis Arends und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Image Sciences, University Medical Center Utrecht, Utrecht, the Netherlands. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Breast. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Eurostars.
Abstract (Originalsprache)
Purpose
Diffusion MRI has shown promise for breast cancer screening, lesion characterization, and treatment response monitoring without contrast agents, but further translation is constrained by the gradient performance of conventional systems. The aim of this work is to develop a single‐axis high‐performance bilateral plug‐and‐play breast gradient insert to enable strong‐gradient diffusion MRI.
Methods
An in‐house breast gradient insert and bed‐tabletop was constructed entirely from commercially available materials, providing a cost‐effective solution compatible with existing MRI systems. Its wiring pattern was optimized for torque and force balancing, power dissipation, and target field performance. Evaluation included gradient field characterization, peripheral nerve stimulation simulation verification, and temperature and eddy current assessment. The setup was used for imaging of a diffusion phantom based on soy lecithin across a range of b values.
Results
Gradient efficiency ranged from 0.61 to 2.8 mT/m/A, enabling diffusion MRI using local strengths up to 420 mT/m (150 A). No peripheral nerve stimulation was observed during tests on five healthy volunteers. Eddy currents were successfully characterized, revealing a linear first order component with an amplitude of 0.03% of the applied gradient field. Imaging experiments demonstrated the feasibility of acquiring b = 10 000 s/mm 2 volumes with a TE of 78 ms, compared with 161 ms when using the scanner gradients (40 mT/m).
Conclusion
This work demonstrates a dedicated bilateral breast gradient insert for safe and feasible strong‐gradient breast diffusion MRI and represents a first step toward dedicated hardware for breast cancer detection and characterization without contrast agents.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Image Sciences, University Medical Center Utrecht, Utrecht, the Netherlands.
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center, University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
ORCID-Profile: Gerrit Cornelis Arends, Edwin Versteeg, Feng Jia, Sebastian Littin
Förderung
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
- Eurostars
Zitieren
APA
Arends, G. C., Versteeg, E., Jia, F., Klomp, D. W. J., Zaitsev, M., Littin, S., & Tax, C. M. W. (2027). Bilateral Breast Gradient Insert Prototype for Strong Diffusion Encoding at 3 T. Magnetic Resonance in Medicine, 97(1), 414-424. https://doi.org/10.1002/mrm.70612
Vancouver
Arends GC, Versteeg E, Jia F, Klomp DWJ, Zaitsev M, Littin S, et al. Bilateral Breast Gradient Insert Prototype for Strong Diffusion Encoding at 3 T. Magnetic Resonance in Medicine. 2027;97(1):414-424. doi:10.1002/mrm.70612
BibTeX
@article{Arends2027,
author = {Arends, Gerrit Cornelis and Versteeg, Edwin and Jia, Feng and Klomp, Dennis W J and Zaitsev, Maxim and Littin, Sebastian and Tax, Chantal M W},
title = {Bilateral Breast Gradient Insert Prototype for Strong Diffusion Encoding at 3 T},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {414--424},
doi = {10.1002/mrm.70612}
}
EUVIMED