Multisite MRI Intravoxel Incoherent Motion Repeatability and Reproducibility across 3 T Scanners in a Breast Diffusion Phantom: A BReast Intravoxel Incoherent Motion Multisite ( BRIMM ) Study
Journal of Magnetic Resonance Imaging · 2024-06 · 59 (6) · 2226-2237
DOI: 10.1002/jmri.29008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 13.09.2023. Verfasst von Dibash Basukala und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, NYU Langone Health, New York City, New Yo…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Diffusion Magnetic Resonance Imaging, Motion. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS.
Abstract (Originalsprache)
Background
Monoexponential apparent diffusion coefficient (ADC) and biexponential intravoxel incoherent motion (IVIM) analysis of diffusion‐weighted imaging is helpful in the characterization of breast tumors. However, repeatability/reproducibility studies across scanners and across sites are scarce.
Purpose
To evaluate the repeatability and reproducibility of ADC and IVIM parameters (tissue diffusivity ( D t ), perfusion fraction ( F p ) and pseudo‐diffusion ( D p )) within and across sites employing MRI scanners from different vendors utilizing 16‐channel breast array coils in a breast diffusion phantom. Study Type Phantom repeatability. Phantom A breast phantom containing tubes of different polyvinylpyrrolidone (PVP) concentrations, water, fat, and sponge flow chambers, together with an MR‐compatible liquid crystal (LC) thermometer. Field Strength/Sequence Bipolar gradient twice‐refocused spin echo sequence and monopolar gradient single spin echo sequence at 3 T. Assessment Studies were performed twice in each of two scanners, located at different sites, on each of 2 days, resulting in four studies per scanner. ADCs of the PVP and water were normalized to the vendor‐provided calibrated values at the temperature indicated by the LC thermometer for repeatability/reproducibility comparisons. Statistical Tests ADC and IVIM repeatability and reproducibility within and across sites were estimated via the within‐system coefficient of variation (wCV). Pearson correlation coefficient ( r ) was also computed between IVIM metrics and flow speed. A P value
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, NYU Langone Health, New York City, New York, USA.
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York City, New York, USA.
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York City, New York, USA.
ORCID-Profile: Dibash Basukala, Katja Pinker, Sunitha B Thakur, Eric E Sigmund
Förderung
- NCI NIH HHS
Zitieren
APA
Basukala, D., Mikheev, A., Sevilimedu, V., Gilani, N., Moy, L., Pinker, K., Thakur, S. B., & Sigmund, E. E. (2024). Multisite MRI Intravoxel Incoherent Motion Repeatability and Reproducibility across 3 T Scanners in a Breast Diffusion Phantom: A BReast Intravoxel Incoherent Motion Multisite ( BRIMM ) Study. Journal of Magnetic Resonance Imaging, 59(6), 2226-2237. https://doi.org/10.1002/jmri.29008
Vancouver
Basukala D, Mikheev A, Sevilimedu V, Gilani N, Moy L, Pinker K, et al. Multisite MRI Intravoxel Incoherent Motion Repeatability and Reproducibility across 3 T Scanners in a Breast Diffusion Phantom: A BReast Intravoxel Incoherent Motion Multisite ( BRIMM ) Study. Journal of Magnetic Resonance Imaging. 2024;59(6):2226-2237. doi:10.1002/jmri.29008
BibTeX
@article{Basukala2024,
author = {Basukala, Dibash and Mikheev, Artem and Sevilimedu, Varadan and Gilani, Nima and Moy, Linda and Pinker, Katja and Thakur, Sunitha B and Sigmund, Eric E},
title = {Multisite MRI Intravoxel Incoherent Motion Repeatability and Reproducibility across 3 T Scanners in a Breast Diffusion Phantom: A BReast Intravoxel Incoherent Motion Multisite ( BRIMM ) Study},
journal = {Journal of Magnetic Resonance Imaging},
year = {2024},
volume = {59},
number = {6},
pages = {2226--2237},
doi = {10.1002/jmri.29008}
}
EUVIMED