Effects of gadolinium-based contrast agents on the cardiac diffusion-weighted images of phantoms and patients
Magnetic Resonance Materials in Physics, Biology and Medicine · 10.04.2026 · 39 (5) · 835-847
DOI: 10.1007/s10334-026-01356-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, online erschienen am 10.04.2026. Verfasst von Satonori Tsuneta und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Nishi5, kita14, kita-ku, Sapporo, Hokkaido, 060-8648, Japan. sat…. Hauptthemen laut MEDLINE: Contrast Media, Gadolinium, Diffusion Magnetic Resonance Imaging, Heart. Die Arbeit nennt 31 Literaturangaben. Gefördert von: JSPS KAKENHI, Hokkaido Heart Association Grant for Research.
Abstract (Originalsprache)
OBJECTIVES: To investigate the effects of gadolinium-based contrast agent (GBCA) on cardiac diffusion-weighted imaging (cDWI) and cDWI feasibility during the interval between GBCA administration and late gadolinium enhancement (LGE) imaging to streamline workflow. MATERIALS AND METHODS: Phantoms containing varying GBCA concentration (0-1.0 mM/L) were scanned with stimulated echo acquisition mode-based cDWI (STEAM-cDWI) with various heart rates (HRs) (30-200 beats/min) and second-order motion-compensated spin-echo-based cDWI (M2SE-cDWI) with various echo times (TEs) (75-500 ms). For patient study, 9 patients underwent STEAM-cDWI and 13 underwent M2SE-cDWI before and after GBCA administration. Contrast ratio (CR) and contrast-to-noise ratio (CNR) between the left ventricular myocardium and cavity, and ADC values were assessed. RESULTS: In phantoms, higher GBCA concentration, lower HR, and prolonged TE reduced SI. In STEAM-cDWI, CR and CNR significantly reduced after GBCA administration (CR of b = 400, 2.29 [1.80-5.46] vs. 1.15 [0.78-1.29], p = 0.0004; CNR of b = 400, 7.58 [4.82-11.1] vs. 0.57 [- 1.34 to 1.35], p = 0.0006; respectively); ADC values remained unchanged. In M2SE-cDWI, ADC values significantly decreased after GBCA administration (1.62 [1.15-1.97] vs. 1.26 [1.12- 1.51], × 10-3 mm2/s respectively, p = 0.004); only CR at b = 400 decreased significantly. DISCUSSION: cDWI is not recommended during the interval between GBCA administration and LGE imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Nishi5, kita14, kita-ku, Sapporo, Hokkaido, 060-8648, Japan. satonori.tsuneta@pop.med.hokudai.ac.jp.
- Department of Radiology, Graduate School of Dental Medicine, Hokkaido University, Nishi7, kita13, kita-ku, Sapporo, Hokkaido, 060-8586, Japan. satonori.tsuneta@pop.med.hokudai.ac.jp.
- Department of Radiological Technology, Hokkaido University Hospital, Nishi5, kita14, kita-ku, Sapporo, Hokkaido, 060-8648, Japan.
- Philips Japan, Ltd, Azabudai Hills Mori JP Tower 15F, 1-3-1 Azabudai, minato-ku, Tokyo, 106-0041, Japan.
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Nishi7, kita15, kita-ku, Sapporo, Hokkaido, 060-8638, Japan.
- Technical Support Center, Graduate School of Medicine, Hokkaido University, Nishi7, kita15, kita-ku, Sapporo, Hokkaido, 060-8638, Japan.
Förderung
- JSPS KAKENHI
- Hokkaido Heart Association Grant for Research
Zitieren
APA
Tsuneta, S., Aono, S., Kwon, J., Yoneyama, M., Uehara, H., Aoike, T., Takenaka, S., Koyano, H., Fujima, N., Nagai, T., Anzai, T., Minowa, K., & Kudo, K. (2026). Effects of gadolinium-based contrast agents on the cardiac diffusion-weighted images of phantoms and patients. Magnetic Resonance Materials in Physics, Biology and Medicine, 39(5), 835-847. https://doi.org/10.1007/s10334-026-01356-5
Vancouver
Tsuneta S, Aono S, Kwon J, Yoneyama M, Uehara H, Aoike T, et al. Effects of gadolinium-based contrast agents on the cardiac diffusion-weighted images of phantoms and patients. Magnetic Resonance Materials in Physics, Biology and Medicine. 2026;39(5):835-847. doi:10.1007/s10334-026-01356-5
BibTeX
@article{Tsuneta2026,
author = {Tsuneta, Satonori and Aono, Satoru and Kwon, Jihun and Yoneyama, Masami and Uehara, Hiroki and Aoike, Takuya and Takenaka, Sakae and Koyano, Hidenori and Fujima, Noriyuki and Nagai, Toshiyuki and Anzai, Toshihisa and Minowa, Kazuyuki and Kudo, Kohsuke},
title = {Effects of gadolinium-based contrast agents on the cardiac diffusion-weighted images of phantoms and patients},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2026},
volume = {39},
number = {5},
pages = {835--847},
doi = {10.1007/s10334-026-01356-5}
}
EUVIMED