EUVIMEDEUVIMED entdecken
Crossref

Fast and efficient extraction and determination of nonsteroidal anti‐inflammatory drugs using poly(8‐hydroxyquinoline)‐coated magnetic graphene oxide nanocomposite prior to capillary electrophoresis analysis in wastewater, breast milk, and urine samples

Abolfath Shahsavani, Ali Reza Fakhari iD

ELECTROPHORESIS · 2024

DOI: 10.1002/elps.202400023 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, 2024. Verfasst von Abolfath Shahsavani und 1 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Chemistry, Shahid Beheshti University, Tehran, I.R. IRAN. Hauptthemen laut MEDLINE: Graphite, Electrophoresis, Capillary, Limit of Detection, Anti-Inflammatory Agents, Non-Steroidal. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Research Affairs of Shahid Beheshti University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, magnetic graphene oxide coated with poly(8‐hydroxyquinoline) was successfully synthesized, characterized, and utilized as a novel sorbent for the ultrasonic‐assisted dispersive magnetic solid‐phase extraction of naproxen and ibuprofen. These analytes served as representative analytes for two nonsteroidal anti‐inflammatory drugs in various real samples. Characterization techniques, such as IR, X‐ray powder diffraction, field emission scanning electron microscopy, energy‐dispersive X‐ray‐mapping, and Brunauer‐Emmett‐Teller (BET), were used to confirm the correctness synthesis and preparation of the nanocomposites. Effective parameters on the extraction efficiency were investigated to maximize the analytical performance of the developed method. The dynamic range (1–1000 µg L −1 ), coefficients of determination ( R 2 ≥ 0.997), the limits of detection (0.3–1.0 µg L −1 ), and limit of quantification (1.0–3.0 µg L −1 ), intra‐day and inter‐day precisions (3.5%–7.2%) were achieved. The method validation results showed extraction recovery ranging from 80.4% to 96.0% and preconcentration factors ranging from 137 to 140.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteElectrophoresis, CapillaryLimit of DetectionAnti-Inflammatory Agents, Non-SteroidalWastewaterSolid Phase ExtractionMilk, HumanHumansReproducibility of ResultsLinear ModelsNanocompositesOxyquinolineWater Pollutants, ChemicalMagnetite Nanoparticles

Stichwörter der Autor:innen

conductive polymeribuprofenmagnetic graphene oxidenaproxenultrasound‐assisted dispersive magnetic solid‐phase extraction

Substanzen

GraphiteAnti-Inflammatory Agents, Non-Steroidalgraphene oxideWastewaterOxyquinolineWater Pollutants, ChemicalMagnetite Nanoparticles

Autor:innen und Institutionen

  • Faculty of Chemistry, Shahid Beheshti University, Tehran, I.R. IRAN.

ORCID-Profile: Ali Reza Fakhari

Förderung

  • Research Affairs of Shahid Beheshti University

Zitieren

APA

Shahsavani, A., & Fakhari, A. R. (2024). Fast and efficient extraction and determination of nonsteroidal anti‐inflammatory drugs using poly(8‐hydroxyquinoline)‐coated magnetic graphene oxide nanocomposite prior to capillary electrophoresis analysis in wastewater, breast milk, and urine samples. ELECTROPHORESIS. https://doi.org/10.1002/elps.202400023

Vancouver

Shahsavani A, Fakhari AR. Fast and efficient extraction and determination of nonsteroidal anti‐inflammatory drugs using poly(8‐hydroxyquinoline)‐coated magnetic graphene oxide nanocomposite prior to capillary electrophoresis analysis in wastewater, breast milk, and urine samples. ELECTROPHORESIS. 2024. doi:10.1002/elps.202400023

BibTeX
@article{Shahsavani2024,
  author = {Shahsavani, Abolfath and Fakhari, Ali Reza},
  title = {Fast and efficient extraction and determination of nonsteroidal anti‐inflammatory drugs using poly(8‐hydroxyquinoline)‐coated magnetic graphene oxide nanocomposite prior to capillary electrophoresis analysis in wastewater, breast milk, and urine samples},
  journal = {ELECTROPHORESIS},
  year = {2024},
  doi = {10.1002/elps.202400023}
}
Kostenlos starten →