EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Enantioselective Determination of Amphetamine‐Type Stimulants in Environmental Waters Using SPE and CE–MS/MS

Pol Clivillé-Cabré, Francesc Borrull, Carme Aguilar, Marta Calull

ELECTROPHORESIS · 2026-03 · 47 (3) · 250-260

DOI: 10.1002/elps.70074 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, online erschienen am 23.01.2026. Verfasst von Pol Clivillé-Cabré und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Tarragona, Spain. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Water Pollutants, Chemical, Solid Phase Extraction, Amphetamines. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: MCIN/AEI, Universitat Rovira i Virgili (URV), Diputació de Tarragona.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The growing concern over drug abuse, particularly involving amphetamine‐type substances (ATS), has led to their monitoring in environmental waters. These chiral compounds, commonly found in river water and wastewater treatment plant (WWTP) effluents, require analytical methods capable of enantiomeric discrimination, as their enantiomers can exhibit different pharmacological and environmental behaviours. A method based on capillary electrophoresis (CE) coupled with tandem mass spectrometry (MS/MS) was developed using a dual cyclodextrin (CD) system consisting of 0.1% 2‐hydroxypropyl‐β‐CD and 0.1% γ‐CD in the background electrolyte (BGE), which enabled baseline resolution of the target enantiomers of the ATS under study. Samples were pretreated with solid‐phase extraction using a mixed‐mode cation exchange sorbent, ExtraBond SCX. Samples of 100 mL for WWTP influent and 250 mL for river water and WWTP effluent were extracted and then eluted with 5 mL of 5% NH 4 OH in methanol. Recoveries ranged between 40% and 67% for all amphetamines studied, with detection limits between 0.1 and 0.8 µg/L. Analysis of environmental samples from the Ebre River and WWTPs in Reus and Tarragona (Catalonia, Spain) confirmed the presence of some of the target compounds. Both enantiomers of 3,4‐methylenedioxymethamphetamine (MDMA) were determined in WWTP influents and effluents, whereas R ‐amphetamine was quantified in an influent sample. No target compounds were detected in the analysed river water samples. These findings demonstrate the potential of the developed chiral CE–MS/MS method for robust enantiomeric profiling in environmental waters, attributed to efficient separation based on differences in effective mobility ( µ eff ), electroosmotic flow ( µ eo ) and selective interactions with CD chiral selectors. The method showed moderate adherence to green analytical principles, achieving an AGREE score of 0.47. Its environmental advantages include the use of CE, minimal solvent consumption and non‐toxic chiral selectors, offering a more suitable alternative to more traditional LC‐based methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryWater Pollutants, ChemicalSolid Phase ExtractionAmphetaminesElectrophoresis, CapillaryStereoisomerismLimit of DetectionWastewaterReproducibility of ResultsRiversCyclodextrinsAmphetamineLinear Models

Stichwörter der Autor:innen

CE–MS/MSamphetamine‐type substancescation‐exchange sorbentschiral separationenvironmental waters

Substanzen

Water Pollutants, ChemicalWastewaterAmphetaminesCyclodextrinsAmphetamine

Autor:innen und Institutionen

  • Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Tarragona, Spain.

Förderung

  • MCIN/AEI
  • Universitat Rovira i Virgili (URV)
  • Diputació de Tarragona

Zitieren

APA

Clivillé-Cabré, P., Borrull, F., Aguilar, C., & Calull, M. (2026). Enantioselective Determination of Amphetamine‐Type Stimulants in Environmental Waters Using SPE and CE–MS/MS. ELECTROPHORESIS, 47(3), 250-260. https://doi.org/10.1002/elps.70074

Vancouver

Clivillé-Cabré P, Borrull F, Aguilar C, Calull M. Enantioselective Determination of Amphetamine‐Type Stimulants in Environmental Waters Using SPE and CE–MS/MS. ELECTROPHORESIS. 2026;47(3):250-260. doi:10.1002/elps.70074

BibTeX
@article{ClivillCabr2026,
  author = {Clivillé-Cabré, Pol and Borrull, Francesc and Aguilar, Carme and Calull, Marta},
  title = {Enantioselective Determination of Amphetamine‐Type Stimulants in Environmental Waters Using SPE and CE–MS/MS},
  journal = {ELECTROPHORESIS},
  year = {2026},
  volume = {47},
  number = {3},
  pages = {250--260},
  doi = {10.1002/elps.70074}
}
Kostenlos starten →