A Self‐Assembly Pipette Tip Restricted Access Mesoporous Polypyrrole Solid‐Phase Extraction Coupled With Capillary Electrophoresis With Diode Array Detection for the Determination of Enalapril in Urine Samples
ELECTROPHORESIS · 2025
DOI: 10.1002/elps.8126 ↗Kurz gefasst
Fachartikel in der Zeitschrift ELECTROPHORESIS, 2025. Verfasst von Iara Amorim Carvalho und 2 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Ciências Naturais, Campus Dom Bosco, Universidade Federal de São João del-Rei, São João del-Rei, Minas Gerais, Brazil. Hauptthemen laut MEDLINE: Polymers, Solid Phase Extraction, Enalapril, Pyrroles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A miniaturized self‐assembly pipette tip with restricted access mesoporous polypyrrole solid‐phase extraction, combined with capillary electrophoresis with diode array detection (CE‐DAD), was developed to rapidly extract and determine enalapril from urine samples. The CE‐DAD technique used 50 mmol L −1 phosphate (pH 7) as the background electrolyte, a voltage of 13 kV, a 30 mbar hydrodynamic injection for 4 s, a capillary temperature of 25°C, and a wavelength of 195 nm to achieve a migration time of 6.3 min with satisfactory peak asymmetry and no interfering and/or baseline noise. The factors that influenced the extraction efficiency were evaluated and optimized: 750 µL sample at pH 7.5, 40 mg adsorbent, 250 µL hexane as a washing solvent, and 750 µL acetonitrile as eluent, resulting in recoveries around 74%. Linearity was acceptable in the 100–3000 ng mL −1 range, and the selectivity and accuracy were also suitable. The limits of detection and quantitation were 30 and 50 ng mL −1 , respectively. The adsorbent effectively removed 87% of the proteins and may be reused three times. The analytical approach was successfully verified and used to analyze enalapril in urine samples collected from volunteers. Finally, the greenness of the researched technique was assessed using five measures that showed good eco‐friendliness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Departamento de Ciências Naturais, Campus Dom Bosco, Universidade Federal de São João del-Rei, São João del-Rei, Minas Gerais, Brazil.
Zitieren
APA
Carvalho, I. A., Silva, C. F., & Borges, K. B. (2025). A Self‐Assembly Pipette Tip Restricted Access Mesoporous Polypyrrole Solid‐Phase Extraction Coupled With Capillary Electrophoresis With Diode Array Detection for the Determination of Enalapril in Urine Samples. ELECTROPHORESIS. https://doi.org/10.1002/elps.8126
Vancouver
Carvalho IA, Silva CF, Borges KB. A Self‐Assembly Pipette Tip Restricted Access Mesoporous Polypyrrole Solid‐Phase Extraction Coupled With Capillary Electrophoresis With Diode Array Detection for the Determination of Enalapril in Urine Samples. ELECTROPHORESIS. 2025. doi:10.1002/elps.8126
BibTeX
@article{Carvalho2025,
author = {Carvalho, Iara Amorim and Silva, Camilla Fonseca and Borges, Keyller Bastos},
title = {A Self‐Assembly Pipette Tip Restricted Access Mesoporous Polypyrrole Solid‐Phase Extraction Coupled With Capillary Electrophoresis With Diode Array Detection for the Determination of Enalapril in Urine Samples},
journal = {ELECTROPHORESIS},
year = {2025},
doi = {10.1002/elps.8126}
}
EUVIMED