Leaflets Morphology Optimization of Valved Pulmonary Arterial Conduit Based on Experimental Design
International Journal for Numerical Methods in Biomedical Engineering · 2026-06 · 42 (6)
DOI: 10.1002/cnm.70185 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, online erschienen am 31.05.2026. Verfasst von Xiaofan Zheng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomechanics, College of Biomedical Engineering, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Pulmonary Artery, Models, Cardiovascular, Heart Valve Prosthesis, Pulmonary Valve. Die Arbeit nennt 22 Literaturangaben. Gefördert von: National Natural Science Foundation of China, 'Med+X' Interdisciplinary Innovation Team Incubation Project of Children's Hospital Affiliated to Fudan University.
Abstract (Originalsprache)
This study investigated the influence of leaflet geometry on the hemodynamic performance of pulmonary valved conduits and optimized leaflet trimming parameters using a design of experiments (DOE) approach combined with in vitro hydrodynamic testing. In vitro hydrodynamic experiments were performed to validate the feasibility of the valved conduit. A computational model was then established based on the experimental setup. DOE was applied to systematically assess and optimize leaflet tailoring parameters. Fluid–structure interaction simulations showed that leaflet tailoring significantly affects hemodynamic outcomes. Reducing leaflet height improved conduit performance. At a cardiac output of 3.5 L/min, the optimized valve exhibited a 3.79% decrease in peak velocity, a 45.18% reduction in maximum equivalent strain, and a 66.57% decrease in coaptation area. These findings suggest that scaling down the free edge length relative to graft diameter and moderately reducing leaflet height may help reduce diastolic regurgitation caused by redundant leaflet overlap while lowering leaflet strain, thereby enhancing valve durability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Biomechanics, College of Biomedical Engineering, Fudan University, Shanghai, China.
- Shanghai Institute of Medical Device Testing, Shanghai, China.
- Children's Heart Center, Children's Hospital of Fudan University, Shanghai, China.
- Zhuhai Fudan Innovation Institute, Zhuhai, Guangdong, China.
ORCID-Profile: Shengzhang Wang
Förderung
- National Natural Science Foundation of China
- 'Med+X' Interdisciplinary Innovation Team Incubation Project of Children's Hospital Affiliated to Fudan University
Zitieren
APA
Zheng, X., Feng, Y., Cai, Y., Yan, W., Shi, Q., Zhang, H., & Wang, S. (2026). Leaflets Morphology Optimization of Valved Pulmonary Arterial Conduit Based on Experimental Design. International Journal for Numerical Methods in Biomedical Engineering, 42(6). https://doi.org/10.1002/cnm.70185
Vancouver
Zheng X, Feng Y, Cai Y, Yan W, Shi Q, Zhang H, et al. Leaflets Morphology Optimization of Valved Pulmonary Arterial Conduit Based on Experimental Design. International Journal for Numerical Methods in Biomedical Engineering. 2026;42(6). doi:10.1002/cnm.70185
BibTeX
@article{Zheng2026,
author = {Zheng, Xiaofan and Feng, Yong and Cai, Yunhan and Yan, Wentao and Shi, Qiqi and Zhang, Huifeng and Wang, Shengzhang},
title = {Leaflets Morphology Optimization of Valved Pulmonary Arterial Conduit Based on Experimental Design},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2026},
volume = {42},
number = {6},
doi = {10.1002/cnm.70185}
}
EUVIMED