Fluid-structure interaction analysis of bioinspired polymeric heart valves with experimental validation
Computer Methods and Programs in Biomedicine · 2025
DOI: 10.1016/j.cmpb.2025.108839 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2025. Verfasst von Xinying Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemical and Biomolecular Engineering, The University of Sydney, NSW, Australia. Electronic address: xinying.liu@sydney.edu.au. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Polymers, Heart Valves. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVES: Valvular heart disease, when not addressed adequately, can result in heart failure, serious heart-related health problems, and in some cases, death. Polymeric heart valves (PHVs) are promising valve replacement technologies that may offer improved durability and better biological performance. Notably, PHVs have the potential to accommodate highly innovative valve designs. Given this feature of PHVs, it is important to shortlist the best performing valve designs prior to committing to extensive in vitro hemodynamic validation prototypes. METHODS: This study presents a computational fluid-structure interaction (FSI) workflow, which integrates computational fluid dynamics (CFD) and finite element analysis (FEA), to simulate the hemodynamic performance of PHVs with two different valve designs under physiological conditions. RESULTS: The model accurately predicts cardiac output (CO), effective orifice area (EOA) and regurgitant fraction (RF) and these predictions have been successfully validated using experimental data. Consistent with experimental findings, increasing valve thickness results in a decrease in EOA, with RF trends varying between different valve designs. The fully opened and unfolded valve exhibited the lowest WSS on the leaflet surfaces. Both valve design and thickness significantly influence stress distribution along the leaflets with the thinnest valves showing lower von Mises stresses during opening and higher stresses during closing. Detailed analysis of flow patterns, wall shear stress (WSS), valve opening and closing behaviors, and mechanical stress distribution are presented. CONCLUSIONS: This work demonstrates the potential of FSI simulations in predicting the hydrodynamic and mechanical behavior of PHVs, offering valuable insights into valve durability and design optimization for improved patient outcomes. This approach can significantly accelerate valve development by reducing reliance on extensive in vitro and in vivo testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemical and Biomolecular Engineering, The University of Sydney, NSW, Australia. Electronic address: xinying.liu@sydney.edu.au.
- School of Chemical and Biomolecular Engineering, The University of Sydney, NSW, Australia.
- LEAP Australia, Clayton North, VIC, Australia.
- DYNAmore, An Ansys Company, Stuttgart, Germany.
- Ann & Robert H. Lurie Children's Hospital of Chicago, Feinberg School of Medicine, Northwestern University, Evanston, IL 60208, USA.
Zitieren
APA
Liu, X., Lee, A., Wang, Y., Hoang, T. P., Yee, K. S., Mosse, L., Karajan, N., Winlaw, D. S., Naficy, S., & Fletcher, D. F. (2025). Fluid-structure interaction analysis of bioinspired polymeric heart valves with experimental validation. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2025.108839
Vancouver
Liu X, Lee A, Wang Y, Hoang TP, Yee KS, Mosse L, et al. Fluid-structure interaction analysis of bioinspired polymeric heart valves with experimental validation. Computer Methods and Programs in Biomedicine. 2025. doi:10.1016/j.cmpb.2025.108839
BibTeX
@article{Liu2025,
author = {Liu, Xinying and Lee, Aeryne and Wang, Yiqi and Hoang, Thanh Phuong and Yee, Karinna Shay and Mosse, Luke and Karajan, Nils and Winlaw, David S and Naficy, Sina and Fletcher, David F},
title = {Fluid-structure interaction analysis of bioinspired polymeric heart valves with experimental validation},
journal = {Computer Methods and Programs in Biomedicine},
year = {2025},
doi = {10.1016/j.cmpb.2025.108839}
}
EUVIMED