Computational Fluid Dynamics Analysis of Artificial Aortic Valves: Impact of Tilted Implantation on Haemodynamics
European Journal of Cardio-Thoracic Surgery · 2026
DOI: 10.1093/ejcts/ezag041 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, 2026. Verfasst von Manuel Berger und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Technologies, MCI-The Entrepreneurial School, 6020 Innsbruck, Austria. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Hemodynamics, Aortic Valve, Models, Cardiovascular. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Prosthesis-patient mismatch (PPM) and tilted implantation in aortic valve replacement can significantly affect haemodynamics, increasing wall shear stress (WSS) and thrombosis risk. This study uses computational fluid dynamics (CFD) to assess the impact of valve size and implantation angle on blood flow in Medtronic Avalus heart valves.
Methods
Computational fluid dynamics (CFD) simulations were conducted using Ansys Fluent to evaluate 3 Medtronic Avalus valve sizes (23 mm, 25 mm, 27 mm) under 2 leaflet-opening configurations. The simulations incorporated physiological boundary conditions, including a steady inlet velocity of 0.3 m/s and a no-slip wall condition. Wall shear stress (WSS) and general shear stress (SS) thresholds were analysed to assess thrombosis risk.
Results
The 25 mm valve reduced the WSS-affected area by 20.83% and the shear stress-affected area by 7.64% compared to the 23 mm valve, demonstrating improved haemodynamics. In contrast, the 27 mm valve increased the WSS-affected area by 41.25% and the shear stress-affected area by 11.26%, with elevated turbulence and recirculation zones near the aortic wall, increasing thrombosis risk.
Conclusions
Moderate upsizing to a 25 mm valve improves haemodynamic performance without introducing adverse flow effects, while further upsizing to 27 mm increases stress and turbulence, raising thrombosis risk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Technologies, MCI-The Entrepreneurial School, 6020 Innsbruck, Austria.
- Department of Industrial Engineering & Management, MCI-The Entrepreneurial School, 6020 Innsbruck, Austria.
- Department of Cardiac Surgery, Medical University of Innsbruck, 6020 Innsbruck, Austria.
ORCID-Profile: Manuel Berger, Thomas Senfter, Lukas Stastny, Christoph Krapf, Can Gollmann-Tepeköylü, Nikolaos Bonaros, Martin Pillei
Zitieren
APA
Berger, M., Golks, J., Gleissner, L., Senfter, T., Mayerl, C., Stastny, L., Grimm, M., Krapf, C., Gollmann-Tepeköylü, C., Bonaros, N., & Pillei, M. (2026). Computational Fluid Dynamics Analysis of Artificial Aortic Valves: Impact of Tilted Implantation on Haemodynamics. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezag041
Vancouver
Berger M, Golks J, Gleissner L, Senfter T, Mayerl C, Stastny L, et al. Computational Fluid Dynamics Analysis of Artificial Aortic Valves: Impact of Tilted Implantation on Haemodynamics. European Journal of Cardio-Thoracic Surgery. 2026. doi:10.1093/ejcts/ezag041
BibTeX
@article{Berger2026,
author = {Berger, Manuel and Golks, Jonna and Gleissner, Lena and Senfter, Thomas and Mayerl, Christian and Stastny, Lukas and Grimm, Michael and Krapf, Christoph and Gollmann-Tepeköylü, Can and Bonaros, Nikolaos and Pillei, Martin},
title = {Computational Fluid Dynamics Analysis of Artificial Aortic Valves: Impact of Tilted Implantation on Haemodynamics},
journal = {European Journal of Cardio-Thoracic Surgery},
year = {2026},
doi = {10.1093/ejcts/ezag041}
}
EUVIMED