EUVIMEDEUVIMED entdecken
Open Access

Enhancing Imaging Performance and Resolution in Magneto‐Acoustic Electrical Tomography With Magnetic Field Measurements ( MAET ‐ MI ) Using Figure‐of‐Eight and High‐Quality Factor Circular Coils

Ahmet Önder Tetik iD, Nevzat Güneri Gençer iD

International Journal for Numerical Methods in Biomedical Engineering · 2025

DOI: 10.1002/cnm.70063 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2025. Verfasst von Ahmet Önder Tetik und 1 weiteren Autor:innen. Beteiligte Einrichtung: Electrical and Electronics Engineering Department, Middle East Technical University, Ankara, Türkiye. Hauptthemen laut MEDLINE: Tomography, Magnetic Fields. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Scientific and Technological Research Council of Türkiye (TÜBİTAK), Türkiye Bilimsel ve Teknolojik Araştırma Kurumu.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magneto‐acousto‐electrical tomography with magnetic field measurement technique (MAET‐MI) is a hybrid imaging method that brings high spatial resolution of ultrasound imaging in electrical impedance tomography. This study investigates the impact of the quality factor of circular and figure‐of‐eight coils on the imaging performance of MAET‐MI. Induced MAET signals on the circular coil are accurately obtained by modeling a circuit representation of an air‐cored circular coil and deriving its transfer function through impedance measurements. The study demonstrates a significant improvement in signal‐to‐noise ratio (SNR) using high‐quality factor coils compared to unity quality factor coils. Additionally, a 16‐element linear phased array (LPA) ultrasound transducer, an air core circular coil, and a figure‐of‐eight coil are numerically modeled to obtain sector scan images of two‐dimensional conductivity distributions. Point spread function (PSF) is characterized, and the lateral resolution of sector scan conductivity images is enhanced through two‐dimensional deconvolution with PSF. The combined use of circular and figure‐of‐eight coils provides comprehensive imaging coverage. Notably, this research presents a practical method for estimating both circular and figure‐of‐eight coils' transfer functions, achieving 12.9 dB SNR improvement with high‐quality factor coils. A simplified breast model is rotated 16 steps, and sector scan conductive boundary images are reconstructed for both coils. A two‐dimensional image of a breast model is obtained by combining images from two different coils. These findings offer significant advancements in MAET‐MI imaging, particularly in low SNR environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TomographyMagnetic FieldsSignal-To-Noise RatioPhantoms, ImagingHumansElectric Impedance

Stichwörter der Autor:innen

coildelay‐and‐sum methodmagneto‐acousto‐electrical tomographyultrasound imagingwiener filter

Autor:innen und Institutionen

  • Electrical and Electronics Engineering Department, Middle East Technical University, Ankara, Türkiye.

ORCID-Profile: Ahmet Önder Tetik, Nevzat Güneri Gençer

Förderung

  • Scientific and Technological Research Council of Türkiye (TÜBİTAK)
  • Türkiye Bilimsel ve Teknolojik Araştırma Kurumu

Zitieren

APA

Tetik, A. Ö., & Gençer, N. G. (2025). Enhancing Imaging Performance and Resolution in Magneto‐Acoustic Electrical Tomography With Magnetic Field Measurements ( MAET ‐ MI ) Using Figure‐of‐Eight and High‐Quality Factor Circular Coils. International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.70063

Vancouver

Tetik AÖ, Gençer NG. Enhancing Imaging Performance and Resolution in Magneto‐Acoustic Electrical Tomography With Magnetic Field Measurements ( MAET ‐ MI ) Using Figure‐of‐Eight and High‐Quality Factor Circular Coils. International Journal for Numerical Methods in Biomedical Engineering. 2025. doi:10.1002/cnm.70063

BibTeX
@article{Tetik2025,
  author = {Tetik, Ahmet Önder and Gençer, Nevzat Güneri},
  title = {Enhancing Imaging Performance and Resolution in Magneto‐Acoustic Electrical Tomography With Magnetic Field Measurements ( MAET ‐ MI ) Using Figure‐of‐Eight and High‐Quality Factor Circular Coils},
  journal = {International Journal for Numerical Methods in Biomedical Engineering},
  year = {2025},
  doi = {10.1002/cnm.70063}
}
Kostenlos starten →