Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self‐Expanding Devices: The CONNAVIPRO Study
Catheterization and Cardiovascular Interventions · 17.08.2026
DOI: 10.1002/ccd.70827 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 17.08.2026. Verfasst von Enrico Poletti und 14 weiteren Autor:innen. Beteiligte Einrichtung: Institut Cardio Vasculaire de Caen (ICVC) - Hôpital Privé, Caen, Saint Martin, France. Hauptthemen laut MEDLINE: Aortic Valve, Aortic Valve Stenosis, Arrhythmias, Cardiac, Cardiac Pacing, Artificial. Die Arbeit nennt 33 Literaturangaben. Gefördert von: Ramsay Santé.
Abstract (Originalsprache)
Background
The Evolut and the Navitor transcatheter heart valves (THVs) represent the most widely used self‐expanding implanted valves. Despite a similar implant concept, they markedly differ in design and hemodynamic performance. In both THVs, conduction disturbances following transcatheter aortic valve replacement (TAVR) are reported higher than in balloon‐expandable devices. Nevertheless, to date, no direct comparative studies have analyzed their real difference rates.
Aim
Aim of the present study was to directly compare the self‐expanding Evolut PRO+ and Navitor THVs, with specific focus on the incidence of new permanent pacemaker implantation (PPI) and post‐procedural hemodynamic performance.
Methods
The CONNAVIPRO registry is an international, multicenter, retrospective study including 880 consecutive patients with severe aortic stenosis treated with Evolut PRO+ ( n = 451) or Navitor ( n = 429) between May 2022 and December 2024. The primary endpoint was new PPI within 30 days among pacemaker‐naïve patients. Secondary endpoints included technical and device success, transprosthetic gradients, and paravalvular leak (PVL). Inverse probability weighting (IPW) was applied to adjust for baseline differences.
Results
Procedural success was high with both valves (97.6%), and early safety outcomes were comparable. At 30 days, the Navitor group showed a higher PPI rate than Evolut (23.2% vs. 17.6%), reaching statistical significance after IPW adjustment (OR 1.53, 95% CI 1.08–2.17; p = 0.018). Mean transprosthetic gradients were slightly higher with Navitor (8 vs. 7 mmHg; p = 0.002), whereas moderate or greater PVL was less frequent (2.8% vs. 7.7%; p < 0.001). Variables independently associated with PPI were hypertension, and pre‐existing right bundle branch block.
Conclusions
Both Evolut PRO+ and Navitor THVs provided excellent safety and hemodynamic outcomes. Navitor may be associated with a higher 30‐day PPI rate, a lower incidence of moderate or greater PVL, and clinically non‐significant higher gradients. These associations should be interpreted as hypothesis‐generating and warrant confirmation in prospective studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institut Cardio Vasculaire de Caen (ICVC) - Hôpital Privé, Caen, Saint Martin, France.
- Structural Heart Department, Rigshospitalet, Copenhagen, Denmark.
- Groupe Cardio Vasculaire Interventionnel (GCVI) Clinique Pasteur, Toulouse, France.
- Interventional Cardiology Unit, IRCCS Multimedica, Sesto San Giovanni, Milan, Italy.
- Interventional Cardiology, De Gasperis Cardio Center, Niguarda Hospital, Piazza Ospedale Maggiore 3, Milan, Italy.
- Department of Medical and Surgical Specialties, ASST Spedali Civili di Brescia, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy.
ORCID-Profile: Enrico Poletti, Omar Alessandro Oliva, Ahmad Hassan, Mauro Massussi, Baydaroglu Nurcan, Antonella Millin, Andrea Raffaele Munafò, Jacopo Oreglia, Federico De Marco, Marianna Adamo
Förderung
- Ramsay Santé
Zitieren
APA
Poletti, E., Oliva, O. A., Hassan, A., Esposito, G., Massussi, M., Ardizzone, V., Nurcan, B., Millin, A., Zuccarelli, V., Munafò, A. R., Oreglia, J., De Marco, F., Adamo, M., Tchetché, D., & Zuffi, A. (2026). Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self‐Expanding Devices: The CONNAVIPRO Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70827
Vancouver
Poletti E, Oliva OA, Hassan A, Esposito G, Massussi M, Ardizzone V, et al. Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self‐Expanding Devices: The CONNAVIPRO Study. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70827
BibTeX
@article{Poletti2026,
author = {Poletti, Enrico and Oliva, Omar Alessandro and Hassan, Ahmad and Esposito, Giuseppe and Massussi, Mauro and Ardizzone, Valentina and Nurcan, Baydaroglu and Millin, Antonella and Zuccarelli, Vittorio and Munafò, Andrea Raffaele and Oreglia, Jacopo and De Marco, Federico and Adamo, Marianna and Tchetché, Didier and Zuffi, Andrea},
title = {Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self‐Expanding Devices: The CONNAVIPRO Study},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70827}
}
EUVIMED