Pacemaker Implantation for Low‐Grade Conduction Abnormalities After Balloon‐Expandable Transcatheter Aortic Valve Implantation
Clinical Cardiology · 2024
DOI: 10.1002/clc.70028 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Cardiology, 2024. Verfasst von Julian Wolfes und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology II-Electrophysiology, University Hospital Münster, Münster, Germany. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Pacemaker, Artificial, Aortic Valve Stenosis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Introduction
A frequent complication after TAVI are postinterventional conduction abnormalities requiring permanent pacemaker implantation. In this study, we analyzed the characteristics of borderline conduction abnormalities leading to pacemaker implantation and the resulting ventricular pacing amounts. Methods and Results All patients who underwent balloon‐expandable TAVI between 2014 and 2019 in our tertiary center were analyzed in a retrospective manner. One hundred and sixty‐five patients of 1083 TAVI‐patients developed postinterventional conduction abnormalities leading to pacemaker implantation. Of these 19 (11.5%) did not represent a clear indication for cardiac pacing according to current European guidelines. Patient characteristics, underlying conduction abnormalities, and the temporal change of ventricular pacing percentages at 24 h and 6 weeks after pacemaker implantation were analyzed. The dominating borderline conduction abnormalities leading to pacemaker implantation were new‐onset persisting bundle‐branch‐blocks and new first‐degree AV‐blocks with progression of AV‐delay. While pacemaker implantation was safe and without severe complications in all cases, only 6 of 19 patients had high pacing amounts (95%−100%) after 24 h while 11 patients had low to no pacing amounts (0%−5%). After 6 weeks, 8 patients showed decreasing pacing amounts, no patient had an increasing amount of ventricular pacing and all patients had an intrinsic ventricular rhythm > 30/min.
Conclusion
In our cohort of 1038 TAVI patients, 19 patients underwent PMI for borderline CAs (11.5% of all PMI). Of these, only 2 patients had high pacing amounts after 6 weeks. The risk of complete persisting heart block in these patients is very low. Furthermore, algorithms to reduce ventricular pacing are highly effective to avoid ventricular pacing whenever reasonable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology II-Electrophysiology, University Hospital Münster, Münster, Germany.
- Department of Cardiology III-Adult Congenital and Valvular Heart Disease, University Hospital Münster, Münster, Germany.
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Wolfes, J., Alba, F. T., Kaleschke, G., Vormbrock, J., Reinke, F., Ellermann, C., Baumgartner, H., Eckardt, L., & Frommeyer, G. (2024). Pacemaker Implantation for Low‐Grade Conduction Abnormalities After Balloon‐Expandable Transcatheter Aortic Valve Implantation. Clinical Cardiology. https://doi.org/10.1002/clc.70028
Vancouver
Wolfes J, Alba FT, Kaleschke G, Vormbrock J, Reinke F, Ellermann C, et al. Pacemaker Implantation for Low‐Grade Conduction Abnormalities After Balloon‐Expandable Transcatheter Aortic Valve Implantation. Clinical Cardiology. 2024. doi:10.1002/clc.70028
BibTeX
@article{Wolfes2024,
author = {Wolfes, Julian and Alba, Fernando de Torres and Kaleschke, Gerrit and Vormbrock, Julia and Reinke, Florian and Ellermann, Christian and Baumgartner, Helmut and Eckardt, Lars and Frommeyer, Gerrit},
title = {Pacemaker Implantation for Low‐Grade Conduction Abnormalities After Balloon‐Expandable Transcatheter Aortic Valve Implantation},
journal = {Clinical Cardiology},
year = {2024},
doi = {10.1002/clc.70028}
}
EUVIMED