EUVIMEDObjevte EUVIMED
VergleichsstudieMultizentrische StudieBeobachtungsstudie

Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self‐Expanding Devices: The CONNAVIPRO Study

Enrico Poletti iD, Omar Alessandro Oliva iD, Ahmad Hassan iD, Giuseppe Esposito, Mauro Massussi iD, Valentina Ardizzone, Baydaroglu Nurcan iD, Antonella Millin iD, Vittorio Zuccarelli, Andrea Raffaele Munafò iD, Jacopo Oreglia iD, Federico De Marco iD and 3 more

Catheterization and Cardiovascular Interventions · 2026-08-17

DOI: 10.1002/ccd.70827 ↗

At a glance

Vergleichsstudie in Catheterization and Cardiovascular Interventions, published online on 2026-08-17. Written by Enrico Poletti and 14 co-authors. Institution: Institut Cardio Vasculaire de Caen (ICVC) - Hôpital Privé, Caen, Saint Martin, France. Major MEDLINE topics: Aortic Valve, Aortic Valve Stenosis, Arrhythmias, Cardiac, Cardiac Pacing, Artificial. 33 references. Funded by: Ramsay Santé.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

The Evolut and the Navitor transcatheter heart valves (THVs) represent the most widely used self‐expanding implanted valves. Despite a similar implant concept, they markedly differ in design and hemodynamic performance. In both THVs, conduction disturbances following transcatheter aortic valve replacement (TAVR) are reported higher than in balloon‐expandable devices. Nevertheless, to date, no direct comparative studies have analyzed their real difference rates.

Aim

Aim of the present study was to directly compare the self‐expanding Evolut PRO+ and Navitor THVs, with specific focus on the incidence of new permanent pacemaker implantation (PPI) and post‐procedural hemodynamic performance.

Methods

The CONNAVIPRO registry is an international, multicenter, retrospective study including 880 consecutive patients with severe aortic stenosis treated with Evolut PRO+ ( n = 451) or Navitor ( n = 429) between May 2022 and December 2024. The primary endpoint was new PPI within 30 days among pacemaker‐naïve patients. Secondary endpoints included technical and device success, transprosthetic gradients, and paravalvular leak (PVL). Inverse probability weighting (IPW) was applied to adjust for baseline differences.

Results

Procedural success was high with both valves (97.6%), and early safety outcomes were comparable. At 30 days, the Navitor group showed a higher PPI rate than Evolut (23.2% vs. 17.6%), reaching statistical significance after IPW adjustment (OR 1.53, 95% CI 1.08–2.17; p = 0.018). Mean transprosthetic gradients were slightly higher with Navitor (8 vs. 7 mmHg; p = 0.002), whereas moderate or greater PVL was less frequent (2.8% vs. 7.7%; p < 0.001). Variables independently associated with PPI were hypertension, and pre‐existing right bundle branch block.

Conclusions

Both Evolut PRO+ and Navitor THVs provided excellent safety and hemodynamic outcomes. Navitor may be associated with a higher 30‐day PPI rate, a lower incidence of moderate or greater PVL, and clinically non‐significant higher gradients. These associations should be interpreted as hypothesis‐generating and warrant confirmation in prospective studies.

Subjects

MeSH terms (MEDLINE)

Aortic ValveAortic Valve StenosisArrhythmias, CardiacCardiac Pacing, ArtificialHeart Valve ProsthesisPacemaker, ArtificialTranscatheter Aortic Valve ReplacementAged, 80 and overFemaleHumansMaleEuropeHemodynamicsIncidenceProsthesis DesignRegistriesRetrospective StudiesRisk AssessmentRisk FactorsSeverity of Illness IndexTime FactorsTreatment Outcome

Author keywords

Evolut PRO+Navitorpacemaker implantationparavalvular leakself‐expanding valvetranscatheter aortic valve replacement

Authors and institutions

  • Institut Cardio Vasculaire de Caen (ICVC) - Hôpital Privé, Caen, Saint Martin, France.
  • Structural Heart Department, Rigshospitalet, Copenhagen, Denmark.
  • Groupe Cardio Vasculaire Interventionnel (GCVI) Clinique Pasteur, Toulouse, France.
  • Interventional Cardiology Unit, IRCCS Multimedica, Sesto San Giovanni, Milan, Italy.
  • Interventional Cardiology, De Gasperis Cardio Center, Niguarda Hospital, Piazza Ospedale Maggiore 3, Milan, Italy.
  • Department of Medical and Surgical Specialties, ASST Spedali Civili di Brescia, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy.

ORCID profiles: Enrico Poletti, Omar Alessandro Oliva, Ahmad Hassan, Mauro Massussi, Baydaroglu Nurcan, Antonella Millin, Andrea Raffaele Munafò, Jacopo Oreglia, Federico De Marco, Marianna Adamo

Funding

  • Ramsay Santé

Cite

APA

Poletti, E., Oliva, O. A., Hassan, A., Esposito, G., Massussi, M., Ardizzone, V., Nurcan, B., Millin, A., Zuccarelli, V., Munafò, A. R., Oreglia, J., De Marco, F., Adamo, M., Tchetché, D., & Zuffi, A. (2026). Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self‐Expanding Devices: The CONNAVIPRO Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70827

Vancouver

Poletti E, Oliva OA, Hassan A, Esposito G, Massussi M, Ardizzone V, et al. Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self‐Expanding Devices: The CONNAVIPRO Study. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70827

BibTeX
@article{Poletti2026,
  author = {Poletti, Enrico and Oliva, Omar Alessandro and Hassan, Ahmad and Esposito, Giuseppe and Massussi, Mauro and Ardizzone, Valentina and Nurcan, Baydaroglu and Millin, Antonella and Zuccarelli, Vittorio and Munafò, Andrea Raffaele and Oreglia, Jacopo and De Marco, Federico and Adamo, Marianna and Tchetché, Didier and Zuffi, Andrea},
  title = {Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self‐Expanding Devices: The CONNAVIPRO Study},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70827}
}
Start for free →