The Sequence of Post‐Dilation Matters: Proximal Optimization Technique (POT) Reduces Longitudinal Stent Deformation Assessed by Intravascular Ultrasound
Catheterization and Cardiovascular Interventions · 23.07.2026
DOI: 10.1002/ccd.70774 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 23.07.2026. Verfasst von Dou Bo-Xu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, First Affiliated Hospital of Harbin Medical University, Harbin, China. Hauptthemen laut MEDLINE: Ultrasonography, Interventional, Stents, Coronary Artery Disease, Angioplasty, Balloon, Coronary. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
Background
Longitudinal stent deformation (LSD) is a potentially serious complication of percutaneous coronary intervention (PCI). Although post‐dilation is a known risk factor for LSD, the influence of procedural factors such as dilation sequence remains poorly understood.
Aims
This study aimed to identify procedural factors associated with LSD, with a focus on post‐dilation technique.
Methods
In 529 patients (533 vessels) undergoing intravascular ultrasound (IVUS)‐guided PCI, stent length was measured after post‐dilation. Patients were categorized based on length change: elongation (> 2 mm or > 10% of nominal stent length; n = 71), unchanged (±2 mm or < 10% of nominal stent length; n = 457), and shortening (> 2 mm or > 10% of nominal stent length; n = 1, likely attributable to measurement error and not statistically significant). Procedural and lesion characteristics were analyzed.
Results
In univariate analysis, post‐dilation sequence ( p < 0.01) and balloon length ( p < 0.05) differed between groups. In multivariate logistic regression, a distal‐to‐proximal dilation sequence (OR 3.13, 95% CI 1.2–10.81) and higher LVEF (OR 1.07, 95% CI 1.02–1.12) were independently associated with stent elongation. Stent placement at ostium was protective (OR 0.45, 95% CI 0.16–0.96). In the elongation group, positive correlations were observed between elongation magnitude and lesion length, stent length, and dilation sequence (all p < 0.05).
Conclusion
The post‐dilation sequence significantly influences LSD. Initiating dilation from the proximal stent segment—known as the proximal optimization technique (POT)—may reduce the risk of stent deformation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, First Affiliated Hospital of Harbin Medical University, Harbin, China.
ORCID-Profile: Dou Bo-Xu
Zitieren
APA
Bo-Xu, D., Zi-Guang, S., & Ji-Yi, Z. (2026). The Sequence of Post‐Dilation Matters: Proximal Optimization Technique (POT) Reduces Longitudinal Stent Deformation Assessed by Intravascular Ultrasound. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70774
Vancouver
Bo-Xu D, Zi-Guang S, Ji-Yi Z. The Sequence of Post‐Dilation Matters: Proximal Optimization Technique (POT) Reduces Longitudinal Stent Deformation Assessed by Intravascular Ultrasound. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70774
BibTeX
@article{BoXu2026,
author = {Bo-Xu, Dou and Zi-Guang, Song and Ji-Yi, Zhao},
title = {The Sequence of Post‐Dilation Matters: Proximal Optimization Technique (POT) Reduces Longitudinal Stent Deformation Assessed by Intravascular Ultrasound},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70774}
}
EUVIMED