EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

When Subtle Guiding Catheter‐Induced Stent Deformation Leads to Abluminal Guidewire Passage: Successful IVUS Tip‐Detection‐Guided Bailout

Yuto Abe iD, Yuya Hirata, Fumimasa Tabata, Tomomi Koizumi

Catheterization and Cardiovascular Interventions · 2026-11 · 108 (6) · 2105-2109

DOI: 10.1002/ccd.70894 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 16.09.2026. Verfasst von Yuto Abe und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, National Hospital Organization Mito Medical Center, Ibaraki, Japan. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Coronary, Cardiac Catheterization, Coronary Artery Disease, Drug-Eluting Stents. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Incomplete stent apposition at the proximal coronary artery may predispose to subtle guiding catheter–induced stent deformation, creating a gap between the stent and the vessel wall that facilitates inadvertent abluminal guidewire passage. We report a case in which balloon dilatation over an unrecognized abluminal guidewire resulted in severe proximal stent deformation and was successfully managed by real‐time IVUS tip‐detection–guided rewiring into the true stent lumen, avoiding additional stent implantation. This case highlights the importance of careful guiding catheter manipulation, meticulous intravascular imaging assessment after guidewire crossing, and IVUS‐guided bailout techniques for the prevention, early recognition, and management of this potentially serious procedural complication.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Angioplasty, Balloon, CoronaryCardiac CatheterizationCoronary Artery DiseaseDrug-Eluting StentsProsthesis FailureStentsUltrasonography, InterventionalHumansMaleCardiac CathetersCoronary AngiographyProsthesis DesignTreatment Outcome

Stichwörter der Autor:innen

abluminal guidewire passageincomplete stent appositionintravascular ultrasoundpercutaneous coronary interventionstent deformation

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, National Hospital Organization Mito Medical Center, Ibaraki, Japan.

ORCID-Profile: Yuto Abe

Zitieren

APA

Abe, Y., Hirata, Y., Tabata, F., & Koizumi, T. (2026). When Subtle Guiding Catheter‐Induced Stent Deformation Leads to Abluminal Guidewire Passage: Successful IVUS Tip‐Detection‐Guided Bailout. Catheterization and Cardiovascular Interventions, 108(6), 2105-2109. https://doi.org/10.1002/ccd.70894

Vancouver

Abe Y, Hirata Y, Tabata F, Koizumi T. When Subtle Guiding Catheter‐Induced Stent Deformation Leads to Abluminal Guidewire Passage: Successful IVUS Tip‐Detection‐Guided Bailout. Catheterization and Cardiovascular Interventions. 2026;108(6):2105-2109. doi:10.1002/ccd.70894

BibTeX
@article{Abe2026,
  author = {Abe, Yuto and Hirata, Yuya and Tabata, Fumimasa and Koizumi, Tomomi},
  title = {When Subtle Guiding Catheter‐Induced Stent Deformation Leads to Abluminal Guidewire Passage: Successful IVUS Tip‐Detection‐Guided Bailout},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  volume = {108},
  number = {6},
  pages = {2105--2109},
  doi = {10.1002/ccd.70894}
}
Kostenlos starten →