Balloon Versus Self‐Expandable TAVI in Patients With Left Ventricular Dysfunction: A Real‐World Comparative Study
Catheterization and Cardiovascular Interventions · 2026-05 · 107 (6) · 1866-1876
DOI: 10.1002/ccd.70547 ↗At a glance
Vergleichsstudie in Catheterization and Cardiovascular Interventions, published online on 2026-03-10. Written by Edward Dababneh and 5 co-authors. Institution: Department of Cardiology, Gold Coast Health Service, Gold Coast, Queensland, Australia. Major MEDLINE topics: Aortic Valve, Aortic Valve Stenosis, Balloon Valvuloplasty, Heart Valve Prosthesis. 17 references.
Abstract (original language)
Background
In severe aortic stenosis with reduced left ventricular ejection fraction (LVEF), transcatheter aortic valve implantation (TAVI) improves systolic function. Self‐expanding valves (SEV) show haemodynamic advantages over balloon‐expandable valves (BEV), but whether this yields greater recovery of left ventricular function remains uncertain.
Objectives
To compare change in ejection fraction between BEV and SEV in adults with LVEF < 40% undergoing TAVI, and to assess haemodynamics and clinical outcomes at 30 days and 12 months.
Methods
Observational cohort using a national registry of adults with LVEF < 40% and no prior myocardial infarction, coronary bypass, or more‐than‐moderate mitral regurgitation. Nearest‐neighbor matching balanced annular perimeter, diameters, and calcification. Echocardiographic outcomes and major adverse cardiac and cerebrovascular events (MACCE) were assessed at 30 days and 12 months. Subgroup analyses stratified patients by annular perimeter ≤ 73.5 or > 73.5 mm.
Results
Of 922 patients, 574 received a BEV and 348 a SEV. Ejection fraction improved by 30 days and was maintained at 12 months, with no between‐group difference. Haemodynamics favored SEV, with lower mean gradients at 30 days and 12 months (both p < 0.001). Clinical outcomes, including MACCE, were similar at 30 days and 12 months, and findings were consistent in small and large annulus strata.
Conclusions
In patients with reduced LVEF, TAVI produced sustained improvement in ejection fraction irrespective of valve platform, and SEV conferred a haemodynamic advantage without differences in ejection fraction or clinical outcomes.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Gold Coast Health Service, Gold Coast, Queensland, Australia.
- Department of Medicine, Griffith University School of Medicine, Gold Coast, Queensland, Australia.
- Institute for Evidence-Based Healthcare, Bond University, Gold Coast, Queensland, Australia.
- Department of Cardiology, Flinders Medical Centre, Adelaide, South Australia, Australia.
- Department of Medicine, University of Adelaide, Adelaide, South Australia, Australia.
Cite
APA
Dababneh, E., Matta, M. G., Niranjan, S., Jones, M., Sinhal, A., & Singh, K. (2026). Balloon Versus Self‐Expandable TAVI in Patients With Left Ventricular Dysfunction: A Real‐World Comparative Study. Catheterization and Cardiovascular Interventions, 107(6), 1866-1876. https://doi.org/10.1002/ccd.70547
Vancouver
Dababneh E, Matta MG, Niranjan S, Jones M, Sinhal A, Singh K. Balloon Versus Self‐Expandable TAVI in Patients With Left Ventricular Dysfunction: A Real‐World Comparative Study. Catheterization and Cardiovascular Interventions. 2026;107(6):1866-1876. doi:10.1002/ccd.70547
BibTeX
@article{Dababneh2026,
author = {Dababneh, Edward and Matta, Maria Gabriela and Niranjan, Selvanayagam and Jones, Mark and Sinhal, Ajay and Singh, Kuljit},
title = {Balloon Versus Self‐Expandable TAVI in Patients With Left Ventricular Dysfunction: A Real‐World Comparative Study},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
volume = {107},
number = {6},
pages = {1866--1876},
doi = {10.1002/ccd.70547}
}
EUVIMED