One‐Year Clinical and Hemodynamic Outcomes in Latest Generation Balloon‐Expandable and Self‐Expandable Transcatheter Heart Valves
Catheterization and Cardiovascular Interventions · 2026
DOI: 10.1002/ccd.70385 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Hirofumi Hioki und 23 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, IMS Tokyo Katsushika General Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Hemodynamics, Transcatheter Aortic Valve Replacement, Aortic Valve. Die Arbeit nennt 21 Literaturangaben. Gefördert von: The OCEAN-TAVI registry is supported by Edwards-Lifesciences, Medtronic, Abbott Vascular, Boston Scientific, and Daiichi-Sankyo company..
Abstract (Originalsprache)
Background
One‐year clinical and hemodynamic outcomes after transcatheter aortic valve replacement (TAVR) using the latest generation balloon‐expandable valve (BEV) and self‐expandable valve (SEV) is not well understood. This study is aimed to compare 1‐year morality and hemodynamics between the latest generation BEV and SEV after TAVR.
Methods
We retrospectively analyzed 1393 patients undergoing TAVR using BEV (63.7%) (SAPIEN3 Ultra RESILIA) and SEV (36.3%) (Evolut FX). The incidence of all‐cause mortality and bioprosthetic valve dysfunction (BVD) over 1‐year were compared between BEV and SEV in both overall and propensity score (PS) matched cohort.
Results
During 1‐year follow‐up, the incidence of all‐cause mortality was comparable between BEV and SEV in the overall (10.8% vs. 8.0%, log‐rank p = 0.30) and PS matched cohort (11.0% vs. 8.9%, log‐rank p = 0.40). The incidence of BVD through 1‐year was also comparable between BEV and SEV in the overall (6.2% vs. 6.9%, p = 0.59) and PS matched cohort (6.7% vs. 8.2%, p = 0.55). Of BVD component, post‐procedural mean pressure gradient more than 20mmH was higher in BEV, while para‐valvular leakage more than moderate was higher in SEV. There was non‐linear relationship between annulus size and BVD, in which TAVR with BEV had higher BVD in a small annulus, while SEV had higher BVD in a large annulus.
Conclusions
In TAVR using the latest generation valves, incidences of mortality and valve performance during 1‐year were comparable between BEV and SEV. Whereas, the impact of annulus size on the difference of valve hemodynamics between BEV and SEV is still observed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, IMS Tokyo Katsushika General Hospital, Tokyo, Japan.
- Department of Cardiology, Toyohashi Heart Center, Toyohashi, Japan.
- Department of Cardiology, Nagoya Heart Center, Nagoya, Japan.
- Department of Cardiology, Gifu Heart Center, Gifu, Japan.
- Department of Cardiology, Kokura Memorial Hospital, Kokura, Japan.
- Department of Cardiology, Tokai University School of Medicine, Isehara, Japan.
ORCID-Profile: Hirofumi Hioki, Masanori Yamamoto, Shinichi Shirai, Kenichi Ishizu, Yohei Ohno, Toru Naganuma, Gaku Nakazawa, Masahiko Noguchi, Masahiko Asami, Daisuke Hachinohe, Hiroshi Ueno, Toshiaki Otsuka, Kentaro Hayashida
Förderung
- The OCEAN-TAVI registry is supported by Edwards-Lifesciences, Medtronic, Abbott Vascular, Boston Scientific, and Daiichi-Sankyo company.
Zitieren
APA
Hioki, H., Yamamoto, M., Shimura, T., Shirai, S., Ishizu, K., Ohno, Y., Yashima, F., Naganuma, T., Watanabe, Y., Yamanaka, F., Nakazawa, G., Noguchi, M., Izumo, M., Asami, M., Nishina, H., Fuku, Y., Hachinohe, D., Ueno, H., Suzuyama, H., …, & OCEAN‐TAVI Investigators (2026). One‐Year Clinical and Hemodynamic Outcomes in Latest Generation Balloon‐Expandable and Self‐Expandable Transcatheter Heart Valves. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70385
Vancouver
Hioki H, Yamamoto M, Shimura T, Shirai S, Ishizu K, Ohno Y, et al. One‐Year Clinical and Hemodynamic Outcomes in Latest Generation Balloon‐Expandable and Self‐Expandable Transcatheter Heart Valves. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70385
BibTeX
@article{Hioki2026,
author = {Hioki, Hirofumi and Yamamoto, Masanori and Shimura, Tetsuro and Shirai, Shinichi and Ishizu, Kenichi and Ohno, Yohei and Yashima, Fumiaki and Naganuma, Toru and Watanabe, Yusuke and Yamanaka, Futoshi and Nakazawa, Gaku and Noguchi, Masahiko and Izumo, Masaki and Asami, Masahiko and Nishina, Hidetaka and Fuku, Yasushi and Hachinohe, Daisuke and Ueno, Hiroshi and Suzuyama, Hiroto and Nishioka, Kenji and Yamasaki, Kazumasa and Otsuka, Toshiaki and Hayashida, Kentaro and OCEAN‐TAVI Investigators, OCEAN‐TAVI Investigators},
title = {One‐Year Clinical and Hemodynamic Outcomes in Latest Generation Balloon‐Expandable and Self‐Expandable Transcatheter Heart Valves},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70385}
}
EUVIMED