Real-Time Fluoroscopic Assessment of Underexpansion Predicts Hemodynamic Valve Deterioration Following TAVR With Balloon-Expandable Device
JACC: Cardiovascular Interventions · 2025-12 · 18 (24) · 3024-3035
DOI: 10.1016/j.jcin.2025.10.005 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Cardiovascular Interventions, 2025-12. Verfasst von Domenico Angellotti und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Department of Advanced Biomedical Science, Un…. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Heart Valve Prosthesis, Hemodynamics, Aortic Valve. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: The clinical sequelae of transcatheter heart valve (THV) underexpansion following transcatheter aortic valve replacement (TAVR) with balloon-expandable devices remain incompletely understood. OBJECTIVES: The aim of this study was to investigate the impact of THV underexpansion on clinical outcomes among patients treated with balloon-expandable TAVR. METHODS: Consecutive patients undergoing transfemoral TAVR with the SAPIEN 3 and SAPIEN 3 Ultra systems in the prospective Bern TAVI registry were retrospectively evaluated. THV underexpansion was assessed on postimplantation fluoroscopic images and quantified using the validated commissural post height method. Significant THV underexpansion was defined as a reduction in stent frame midportion diameter ≥20% compared with the nominal diameter, using an optimal cutoff value determined by maximizing the log-rank statistic. The outcomes of interest were moderate or severe hemodynamic valve deterioration (HVD) according to the Valve Academic Research Consortium 3 and all-cause and cardiovascular mortality at 5-year follow-up. RESULTS: Among 1,043 patients (median age 81 years; Q1-Q3: 76-85 years; 34.6% women) undergoing TAVR with SAPIEN 3 or SAPIEN 3 Ultra valves between 2014 and 2022, 57 (5.4%) exhibited THV underexpansion. THV underexpansion ≥ 20% was associated with an increased risk for HVD at 5-year follow-up (subdistribution HR: 4.88; 95% CI: 2.18-10.97). The risk for HVD gradually increased with increasing degree of underexpansion (subdistribution HR: 1.94 per 5% increase; 95% CI: 1.42-2.79), with consistent findings across all valve sizes. Total aortic valve calcium volume, bicuspid anatomy, and valve iteration were significant predictors of THV underexpansion. At 862-day follow-up (Q1-Q3: 366-1,812 days), underexpansion was not associated with mortality. CONCLUSIONS: Underexpansion of balloon-expandable THVs is associated with an increased risk for HVD at mid-term follow-up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Department of Advanced Biomedical Science, University of Naples Federico II, Naples, Italy.
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
- Department of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
- Department of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Electronic address: david.meier@chuv.ch.
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland. Electronic address: thomas.pilgrim@insel.ch.
Zitieren
APA
Angellotti, D., Elamin, N., Ferro, C., Tomii, D., Lanz, J., Stortecky, S., Alaour, B., Bartkowiak, J., Samim, D., Praz, F., Reineke, D., Muller, O., Windecker, S., Meier, D., & Pilgrim, T. (2025). Real-Time Fluoroscopic Assessment of Underexpansion Predicts Hemodynamic Valve Deterioration Following TAVR With Balloon-Expandable Device. JACC: Cardiovascular Interventions, 18(24), 3024-3035. https://doi.org/10.1016/j.jcin.2025.10.005
Vancouver
Angellotti D, Elamin N, Ferro C, Tomii D, Lanz J, Stortecky S, et al. Real-Time Fluoroscopic Assessment of Underexpansion Predicts Hemodynamic Valve Deterioration Following TAVR With Balloon-Expandable Device. JACC: Cardiovascular Interventions. 2025;18(24):3024-3035. doi:10.1016/j.jcin.2025.10.005
BibTeX
@article{Angellotti2025,
author = {Angellotti, Domenico and Elamin, Nadir and Ferro, Cyril and Tomii, Daijiro and Lanz, Jonas and Stortecky, Stefan and Alaour, Bashir and Bartkowiak, Joanna and Samim, Daryoush and Praz, Fabien and Reineke, David and Muller, Olivier and Windecker, Stephan and Meier, David and Pilgrim, Thomas},
title = {Real-Time Fluoroscopic Assessment of Underexpansion Predicts Hemodynamic Valve Deterioration Following TAVR With Balloon-Expandable Device},
journal = {JACC: Cardiovascular Interventions},
year = {2025},
volume = {18},
number = {24},
pages = {3024--3035},
doi = {10.1016/j.jcin.2025.10.005}
}
EUVIMED