EUVIMEDScopri EUVIMED
Systematische ÜbersichtMetaanalyse

Long‐Term Durability of Balloon‐Expandable Versus Self‐Expanding Transcatheter Aortic Valves: A Systematic Review and Meta‐Analysis

Saverio Continisio, Andrea R Munafò iD, Carolina Montonati, Riccardo Terzi, Emiliano Boldi, Alfonso Ielasi, Claudio Montalto iD, Francesco Soriano, Jacopo A Oreglia, Federico De Marco iD, Antonio Silvestro, Tommaso Fabris and 8 more

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70294 ↗

At a glance

Systematische Übersicht in Catheterization and Cardiovascular Interventions, 2026. Written by Saverio Continisio and 19 co-authors. Institution: Division of Cardiology, Clinica S. Rocco di Franciacorta, Brescia, Italy. Major MEDLINE topics: Aortic Valve, Aortic Valve Stenosis, Balloon Valvuloplasty, Bioprosthesis. Cited 1 times so far (Crossref); 50 references. Funded by: The authors received no specific funding for this work..

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Transcatheter aortic valve replacement (TAVR) for aortic stenosis (AS) is increasingly performed in younger patients with long life expectancy. However, limited data exist on the durability of transcatheter heart valves (THVs).

Aims

The aim of the present work is to compare the long‐term durability of balloon‐expandable (BEV) and self‐expanding (SEV) THVs after TAVR.

Methods

Electronic databases were searched up to May 2025 for studies reporting on the long‐term durability of THVs in patients undergoing TAVR with a minimum follow‐up of 5 years. Pooled odds ratios (ORs) with 95% confidence interval (CI) were used as summary statistics and were calculated using a random‐effects model. Co‐primary endpoints were moderate and severe structural valve deterioration (SVD) and the occurrence of all‐cause bioprosthetic valve failure (BVF). All‐cause death was the secondary endpoint.

Results

A total of 22 studies and 12,131 patients undergoing TAVR were included: 52.5% of patients ( n = 6362) received BEV, 47.5% ( n = 5769) SEV. An old‐generation THV was used in 84.5% of cases. At a median follow‐up of 7 (5−8.3) years, the overall pooled estimates of moderate/severe SVD and BVF were 7% (5−9) and 4% (3−5), respectively. Patients treated with a BEV experienced a higher rate of SVD (OR: 2.09; 95% CI: 1.58−2.75; p < 0.001) and BVF (OR: 1.61; 95% CI: 1.10−2.36; p = 0.014); no difference was observed in terms of all‐cause death.

Conclusions

At long‐term follow‐up after TAVR, patients receiving a BEV experienced higher rates of moderate/severe SVD and of BVF compared to those having a SEV. However, no significant differences between the two THV designs were observed on the clinical endpoint of all‐cause death.

Subjects

MeSH terms (MEDLINE)

Aortic ValveAortic Valve StenosisBalloon ValvuloplastyBioprosthesisHeart Valve ProsthesisProsthesis FailureTranscatheter Aortic Valve ReplacementHumansProsthesis DesignRisk AssessmentRisk FactorsTime FactorsTreatment Outcome

Author keywords

TAVRbioprosthetic valve failuredurabilitystructural valve deterioration

Authors and institutions

  • Division of Cardiology, Clinica S. Rocco di Franciacorta, Brescia, Italy.
  • De Gasperis Cardio Center, Interventional Cardiology Unit, Niguarda Hospital, Milan, Italy.
  • Division of Cardiology, IRCCS Hospital Galeazzi-Sant'Ambrogio, Milan, Italy.
  • Department of Cardiology, Monzino Cardiology Center, Milan, Italy.
  • School of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy.
  • Department of Cardiac, Thoracic and Vascular Sciences and Public Health, University of Padova, Padua, Italy.

ORCID profiles: Andrea R Munafò, Claudio Montalto, Federico De Marco, Francesco Saia, Azeem Latib, Andrea Scotti

Funding

  • The authors received no specific funding for this work.

Cite

APA

Continisio, S., Munafò, A. R., Montonati, C., Terzi, R., Boldi, E., Ielasi, A., Montalto, C., Soriano, F., Oreglia, J. A., Marco, F., Silvestro, A., Fabris, T., Ho, E., Saia, F., Tarantini, G., Godino, C., Maisano, F., Tang, G. H. L., Latib, A., & Scotti, A. (2026). Long‐Term Durability of Balloon‐Expandable Versus Self‐Expanding Transcatheter Aortic Valves: A Systematic Review and Meta‐Analysis. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70294

Vancouver

Continisio S, Munafò AR, Montonati C, Terzi R, Boldi E, Ielasi A, et al. Long‐Term Durability of Balloon‐Expandable Versus Self‐Expanding Transcatheter Aortic Valves: A Systematic Review and Meta‐Analysis. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70294

BibTeX
@article{Continisio2026,
  author = {Continisio, Saverio and Munafò, Andrea R and Montonati, Carolina and Terzi, Riccardo and Boldi, Emiliano and Ielasi, Alfonso and Montalto, Claudio and Soriano, Francesco and Oreglia, Jacopo A and Marco, Federico De and Silvestro, Antonio and Fabris, Tommaso and Ho, Edwin and Saia, Francesco and Tarantini, Giuseppe and Godino, Cosmo and Maisano, Francesco and Tang, Gilbert H L and Latib, Azeem and Scotti, Andrea},
  title = {Long‐Term Durability of Balloon‐Expandable Versus Self‐Expanding Transcatheter Aortic Valves: A Systematic Review and Meta‐Analysis},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70294}
}
Start for free →