Impact of Balloon Postdilation on Long-Term Bioprosthesis Durability After TAVR
Circulation: Cardiovascular Interventions · 2025-12 · 18 (12)
DOI: 10.1161/circinterventions.125.015577 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation: Cardiovascular Interventions, 2025-12. Verfasst von Antonin Trimaille und 11 weiteren Autor:innen. Beteiligte Einrichtung: Quebec Heart & Lung Institute, Laval University, Canada. Hauptthemen laut MEDLINE: Bioprosthesis, Heart Valve Prosthesis, Transcatheter Aortic Valve Replacement, Aortic Valve. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: While balloon postdilation (BPD) during transcatheter aortic valve replacement may enhance hemodynamic performance by optimizing valve expansion, it was also linked with leaflet mechanical stress, potentially reducing valve durability. The aim of this study was to investigate the impact of BPD on long-term bioprosthetic valve durability. METHODS: We analyzed the data of a prospective single-center registry including consecutive patients undergoing transcatheter aortic valve replacement between May 2007 and March 2024 alive at 1-year and without a valve-in-valve procedure. To reduce imbalance in baseline and procedural characteristics, the effect of BPD on events was assessed using a propensity score-matched population (215 patients with BPD versus 761 patients without BPD, out of a total of 1911 patients). The primary end point was the occurrence of stage 2 or 3 hemodynamic valve deterioration according to Valve Academic Research Consortium-3. RESULTS: In the propensity-score matched population, BPD was associated with a lower risk of stage 2 or 3 hemodynamic valve deterioration occurrence compared with no-BPD (2.8% versus 5.8%; subdistribution hazard ratio, 0.37 [95% CI, 0.15–0.95]; P =0.039), and a lower rate of bioprosthetic valve failure (2.8% versus 5.1%; subdistribution hazard ratio, 0.39 [95% CI, 0.15–0.98]; P =0.046). Long-term echocardiographic follow-up up to 10 years showed better hemodynamic parameters over time in patients with BPD. A trend toward a higher prevalence of heart failure hospitalization was observed in patients with BPD. CONCLUSIONS: BPD was associated with a lower incidence of stage 2 and 3 hemodynamic valve deterioration and bioprosthetic valve failure, along with improved bioprosthetic valve hemodynamic parameters over time. Further studies are warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Quebec Heart & Lung Institute, Laval University, Canada.
ORCID-Profile: Antonin Trimaille, Pedro Cepas-Guillén, Juan Hernando Del Portillo, Carlos Giuliani, Jean-Michel Paradis, Frederic Beaupré, Siamak Mohammadi, Josep Rodés-Cabau
Zitieren
APA
Trimaille, A., Cepas-Guillén, P., Del Portillo, J. H., Giuliani, C., Paradis, J. M., Dumont, E., Poulin, A., Kalavrouziotis, D., Beaupré, F., Porterie, J., Mohammadi, S., & Rodés-Cabau, J. (2025). Impact of Balloon Postdilation on Long-Term Bioprosthesis Durability After TAVR. Circulation: Cardiovascular Interventions, 18(12). https://doi.org/10.1161/circinterventions.125.015577
Vancouver
Trimaille A, Cepas-Guillén P, Del Portillo JH, Giuliani C, Paradis JM, Dumont E, et al. Impact of Balloon Postdilation on Long-Term Bioprosthesis Durability After TAVR. Circulation: Cardiovascular Interventions. 2025;18(12). doi:10.1161/circinterventions.125.015577
BibTeX
@article{Trimaille2025,
author = {Trimaille, Antonin and Cepas-Guillén, Pedro and Del Portillo, Juan Hernando and Giuliani, Carlos and Paradis, Jean-Michel and Dumont, Eric and Poulin, Anthony and Kalavrouziotis, Dimitri and Beaupré, Frederic and Porterie, Jean and Mohammadi, Siamak and Rodés-Cabau, Josep},
title = {Impact of Balloon Postdilation on Long-Term Bioprosthesis Durability After TAVR},
journal = {Circulation: Cardiovascular Interventions},
year = {2025},
volume = {18},
number = {12},
doi = {10.1161/circinterventions.125.015577}
}