Balloon Trapping Technique With a Guide Extension Catheter for Retrieval of a Stuck Coronary Guidewire: A Case Report
Catheterization and Cardiovascular Interventions · 2025-10 · 106 (4) · 2601-2606
DOI: 10.1002/ccd.70104 ↗At a glance
Fallbericht in Catheterization and Cardiovascular Interventions, published online on 2025-08-19. Written by Taishi Fukushima and 3 co-authors. Institution: Department of Cardiology, Nagoya University, Nagoya, Japan. Major MEDLINE topics: Angioplasty, Balloon, Coronary, Cardiac Catheters, Coronary Occlusion, Device Removal. Cited 1 times so far (Crossref); 6 references. Funded by: The authors received no specific funding for this work..
Abstract (original language)
Guidewire entrapment beneath a coronary stent is an uncommon but potentially serious complication of percutaneous coronary intervention. Forcible traction of the stuck guidewire may cause structural breakdown of guidewire or stent, potentially resulting in thrombus formation or vessel injuries. We report a case of in‐stent chronic total occlusion of the left anterior descending artery. After deployment of a drug‐eluting stent in the overlapping fashion, the jailed guidewire in a diagonal branch could not be retrieved using standard techniques, such as advancing a microcatheter or small‐balloon close to the stent. Therefore, we advanced a 5 Fr guide extension catheter (GEC) over the jailed guidewire, positioning it close to the deployed stent. A balloon catheter was inflated alongside the jailed guidewire to trap and fix it within the GEC. This assembly—guidewire, balloon, and GEC—could be removed smoothly without stent deformation or vessel injury. To our knowledge, this is the first report of entrapped guidewire successfully retrieved with balloon trapping technique using a GEC. This technique provides controlled countertraction, minimizes the risk of complications, and may serve as a reproducible bailout option when conventional methods fail to retrieve the stuck guidewire.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Nagoya University, Nagoya, Japan.
- Department of Cardiology, Fujita Health University Bantane Hospital, Nagoya, Japan.
- Department of Cardiology, Fujita Health University Hospital, Toyoake, Japan.
- Department of Cardiology, Mie Heart Center, Mie, Japan.
ORCID profiles: Taishi Fukushima, Masataka Yoshinaga
Funding
- The authors received no specific funding for this work.
Cite
APA
Fukushima, T., Yoshinaga, M., Muramatsu, T., & Nasu, K. (2025). Balloon Trapping Technique With a Guide Extension Catheter for Retrieval of a Stuck Coronary Guidewire: A Case Report. Catheterization and Cardiovascular Interventions, 106(4), 2601-2606. https://doi.org/10.1002/ccd.70104
Vancouver
Fukushima T, Yoshinaga M, Muramatsu T, Nasu K. Balloon Trapping Technique With a Guide Extension Catheter for Retrieval of a Stuck Coronary Guidewire: A Case Report. Catheterization and Cardiovascular Interventions. 2025;106(4):2601-2606. doi:10.1002/ccd.70104
BibTeX
@article{Fukushima2025,
author = {Fukushima, Taishi and Yoshinaga, Masataka and Muramatsu, Takashi and Nasu, Kenya},
title = {Balloon Trapping Technique With a Guide Extension Catheter for Retrieval of a Stuck Coronary Guidewire: A Case Report},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
volume = {106},
number = {4},
pages = {2601--2606},
doi = {10.1002/ccd.70104}
}