Successful Tip Detection‐Antegrade Dissection and Re‐Entry for Chronic Iatrogenic Coronary Artery Dissection Using a 6Fr Guiding Catheter: A Technical Challenge Overcome
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70102 ↗Kurz gefasst
Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Bayushi Eka Putra und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Sapporo Cardiovascular Clinic, Sapporo Heart Center, Sapporo, Japan. Hauptthemen laut MEDLINE: Cardiac Catheters, Iatrogenic Disease, Cardiac Catheterization, Aortic Dissection. Die Arbeit nennt 11 Literaturangaben.
Abstract (Originalsprache)
A 57‐year‐old man presented with recurrent exertional angina 1 month after an unsuccessful PCI attempt elsewhere. Angiography revealed severe stenosis and a chronic dissection of the posterior lateral artery (PLA). PCI was performed via a 6 Fr right transradial guiding catheter. Initial intravascular ultrasound (IVUS) using OptiCross HD (Boston Scientific; 3.1 Fr outer diameter [OD], 20 mm transducer‐to‐tip distance [TTD]) confirmed guidewire placement in the subintimal space within the extensive chronic dissection. TD‐ADR was successfully performed using the OptiCross HD IVUS and a low‐profile Carnelian MARVEL microcatheter (1.9 Fr OD), both accommodated within the 6 Fr guide. True lumen re‐entry was achieved, followed by balloon dilatation, side branch management, and successful drug‐eluting stent deployment in the main vessel, confirmed by final angiography and IVUS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Sapporo Cardiovascular Clinic, Sapporo Heart Center, Sapporo, Japan.
- Department of Cardiology, Berkah General Hospital Pandeglang, Kabupaten Pandeglang, Banten, Indonesia.
ORCID-Profile: Bayushi Eka Putra, Umihiko Kaneko, Yutaka Tadano, Tsutomu Fujita
Zitieren
APA
Putra, B. E., Kaneko, U., Tadano, Y., & Fujita, T. (2025). Successful Tip Detection‐Antegrade Dissection and Re‐Entry for Chronic Iatrogenic Coronary Artery Dissection Using a 6Fr Guiding Catheter: A Technical Challenge Overcome. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70102
Vancouver
Putra BE, Kaneko U, Tadano Y, Fujita T. Successful Tip Detection‐Antegrade Dissection and Re‐Entry for Chronic Iatrogenic Coronary Artery Dissection Using a 6Fr Guiding Catheter: A Technical Challenge Overcome. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70102
BibTeX
@article{Putra2025,
author = {Putra, Bayushi Eka and Kaneko, Umihiko and Tadano, Yutaka and Fujita, Tsutomu},
title = {Successful Tip Detection‐Antegrade Dissection and Re‐Entry for Chronic Iatrogenic Coronary Artery Dissection Using a 6Fr Guiding Catheter: A Technical Challenge Overcome},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70102}
}
EUVIMED